<REAR

TERMINAL SETTINGS>

OFF

MODE

OUT

1

 

MODE

OUT

2

 

OFF

MODE

OUT

3

 

OFF

MODE

OUT

4

 

OFF

MODE

OUT

5

 

OFF

>>KEY SOUND

 

 

ON

BUZZER

 

 

OFF

REMAIN HDD

MAIN-10%

CALL OUT SETTINGS

 

10M

EMERGENCY REC DURATION

1.Press the SET UP button } <SETTINGS> } <INITIAL SET UP/INFORMATION> } Select “KEY SOUND” in the <REAR TERMINAL SETTINGS> screen. Display the desired setting and confirm.

2.Turn the SHUTTLE ring counterclockwise or press the SET UP button to exit.

BUZZER

It is possible for a buzzer to sound when the remaining HDD device or archive device space reaches the value set in “REMAIN HDD” of the <REAR TERMINAL SET- TINGS> screen. Other than the above, it is possible to set the buzzer to sound when starting alarm recording or emergency recording, or when a warning is displayed.

<REAR

TERMINAL SETTINGS>

OFF

MODE

OUT

1

 

MODE

OUT

2

 

OFF

MODE

OUT

3

 

OFF

MODE

OUT

4

 

OFF

MODE

OUT

5

 

OFF

KEY SOUND

 

 

ON

>>BUZZER

 

 

OFF

REMAIN HDD

MAIN-10%

CALL OUT SETTINGS

 

10M

EMERGENCY REC DURATION

To sound a buzzer only when reaching a specified value :

1)Select “REMAIN” for “BUZZER” in the <REAR TER- MINAL SETTINGS> screen.

2)Set the remaining capacity in “REMAIN HDD” of the <REAR TERMINAL SETTINGS> screen.

To sound a buzzer when reaching the set remaining capacity or when a warning is displayed :

1)Select “WARNING” for “BUZZER” in the <REAR TER- MINAL SETTINGS> screen.

2)Set the remaining HDD capacity (HDD MAIN RE- MAIN/HDD SUB REMAIN/ARCHIVE REMAIN) in “CALL OUT SETTINGS” of the <REAR TERMINAL SET- TINGS> screen.

Setting ( default : “OFF” )

“REMAIN”, “WARNING”, “ALARM”, “OFF

SETTING

REMAIN

WARNING ALARM OFF

BUZZER

 

 

 

 

 

 

 

 

 

When reaching the remaining

ON

OFF

OFF

OFF

capacity set in “REMAIN HDD”

 

 

 

 

 

 

 

 

 

When a failure occurs and

OFF

ON

OFF

OFF

a warning is displayed

 

 

 

 

 

 

 

 

 

When an alarm recording or

OFF

OFF

ON

OFF

emergency recording is started

 

 

 

 

 

 

 

 

 

1.Press the SET UP button } <SETTINGS> } <INITIAL SET UP/ INFORMATION> } Select “BUZZER” in the <REAR TERMINAL SETTINGS> screen. Display the desired setting and confirm.

2.Turn the SHUTTLE ring counterclockwise or press the SET UP button to exit.

REMAIN HDD

A warning indicating that either remaining capacity of HDD or archive device has become full during record- ing is outputted.

<REAR

TERMINAL SETTINGS>

OFF

MODE

OUT

1

 

MODE

OUT

2

 

OFF

MODE

OUT

3

 

OFF

MODE

OUT

4

 

OFF

MODE

OUT

5

 

OFF

KEY SOUND

 

 

ON

BUZZER

 

 

OFF

>>REMAIN HDD

MAIN-10%

CALL OUT SETTINGS

 

10M

EMERGENCY REC DURATION

A warning is outputted using the following methods when the remaining capacity becomes low during re- cording.

The HDD usage display flashes when “3” is set to “DISPLAY MODE” in the <TIME DATE/DISPLAY SET- TINGS> screen.

A buzzer will sound when “REMAIN” is set to “BUZZER” in the <REAR TERMINAL SETTINGS> screen.

Setting of DEVICE ( default : “MAIN” )

“MAIN” : Displays a warning of low MAIN HDD capacity.

“SUB” : Displays a warning of low SUB HDD capacity.

“ARCHIVE” : Displays a warning of low archive device capacity.

“OFF” : Does not display warning of low capacity.

“SUB” appears when “PARTITION” is selected on “HDD SETTING” of the <INITIALIZATION> screen.

Setting of “REMAIN HDD” ( default : “10%” )

“2%”, “4%”, “6%”, “8%”, “10%”, “15%”,“20%”, “30%”, “40%”, “50%”

1.Press the SET UP button } <SETTINGS> } <INITIAL SET UP/INFORMATION> } “Select “REMAIN HDD” in the <REAR TERMINAL SETTINGS> screen and turn the SHUTTLE ring clockwise twice.

The setting display reverses in color when the SHUTTLE ring is turned the first time. When the ring is turned for the second time, the background turns red and flashes.

2.Turn the JOG dial to display the desired device and turn the SHUTTLE ring clockwise.

The setting is confirmed and flashing stops.

3.Turn the JOG dial clockwise to move the reversed display to the REMAIN HDD value and turn the SHUTTLE ring clockwise.

The background of the REMAIN HDD value turns red and flashes.

4.Turn the JOG dial to display the desired capacity and turn the SHUTTLE ring clockwise.

The setting is confirmed and flashing stops.

5.Turn the SHUTTLE ring counterclockwise or press the SET UP button.

••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••

Operations

57

Page 57
Image 57
Mitsubishi Electronics DX-TL2500U Buzzer, Setting of Device default Main, Setting of Remain HDD default 10%