<TIMER PROGRAM SETTINGS>

TIMER PROGRAM SETTINGS

Up to 3 operation patterns can be set in advance. By indi- vidually setting the camera, recording intervals and re- cording picture quality for normal recording/alarm record- ing to REC MODE A ~ D, settings can be changed in- stantly by simple switching selections.

Before recording, accurately set the date and cur-

rent time (for setting the date and time, see pages 25, 26).

TIMER PROGRAM

Structure of the <TIMER PROGRAM> screen

1)

2)

3)

4)

5)

6)

7) 8)

 

 

<TIMER PROGRAM>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P1

 

 

 

DW

START

END

MODE

 

MD

 

>>1

 

--:

 

 

:

 

 

-

 

 

---

--

----

 

 

 

2

---

--:--

--

:--

----

 

-

 

 

3

---

--:--

--

:--

----

 

-

 

 

4

---

--:--

--

:--

----

 

-

 

 

5

---

--:--

--

:--

----

 

-

 

 

6

---

--:--

--

:--

----

 

-

 

 

7

---

--:--

--

:--

----

 

-

 

 

8

---

--:--

--

:--

----

 

-

 

 

SPL

SAT-SUN

 

 

 

 

 

9)

1) PROGRAM NUMBER

Up to 8 programs can be set for a single operation.

2) DW

The day of week from “SUN” to “SAT” can be set. “DAY” : When recording at the same time daily.

“SPL” : When recording the period specified in “9) SPL (special day of the week setting)” below.

“HOL” : When setting holidays specified in the <HOLI- DAY SETTING> screen.

3) REC START TIME

The time is indicated using the 24-hour system.

If there is an overlap in the reservation time, the program with the larger program number (1 - 8, 8 be- ing larger) is given priority for recording.

4) NEXT DAY

Next day mark appears when recording is to be carried over to the following day.

5)REC END TIME

6)MODE

“A” ~ “D” : Separate REC MODE, each MODE can be set and can function separately from each other (for details

concerning REC mode settings, see pages 27, 28, 47-49).

“SKIP” : When temporarily skipping timer recording (the recording will not be made for the specified time frame of that program number).

“OVER” : Performs archive after deleting all previous data on the ARCHIVE device.

“OVER-E” : Performs archive after deleting all previous data on the ARCHIVE device, and automatically ejects media after completion of archive.

“CONT” : Performs archive following the end of the pre- vious data on the ARCHIVE device.

“CONT-E” : Performs archive following the end of the previous data on the ARCHIVE device, and automati- cally ejects media after completion of archive.

Set the start and finish times at least 10 minutes apart when performing archive with Timer settings.

Timer recording does not recognise the “ARCHIVE MEDIA AUTO EJECT” even if it is set to “ON”. Set the “MODE” to “OVER-E” or “CONT-E” on the <TIMER PROGRAM> screen.

7) MD

The motion detection function can be set to ON/OFF.

8)Selected pattern number (P1 ~ P3) is displayed.

9)SPL (special day of the week setting)

The start day of the week and end day of the week are set. When selecting “SPL” in “DW”, the period from the start day of the week and end day of the week set are active.

Example : Using program 1 in <TIMER PROGRAM> P2, REC MODE A will record to Wednesday ~ Saturday from 12:30 to 13:00 and “MD” is set to “ON”.

1.Press the SET UP button } <SETTINGS> } select “TIMER PROGRAM SETTINGS”.

<TIMER PROGRAM SETTINGS>

P1-SET

>>SELECTED

PATTERN

HOLIDAY SETTING

 

REC MODE

A

 

REC MODE

B

 

REC MODE

C

 

REC MODE

D

5S

ALARM REC DURATION

2.Check to see that the cursor is to the left of “SELECTED PATTERN” and turn the SHUTTLE ring clockwise twice.

The “P1” display reverses in color when the SHUTTLE ring is turned the first time. When the ring is turned for the second time, the background turns red and flashes.

3.Turn the JOG dial to select “P2” and turn the SHUTTLE ring clockwise.

The setting is confirmed and flashing stops.

4.Turn the JOG dial clockwise to reverse display “SET” and turn the SHUTTLE ring clockwise.

The <TIMER PROGRAM> screen appears.

<TIMER PROGRAM>

 

P2

DW

START END MODE

MD

>>1 ---

--:-- --

:-- ----

-

2 ---

--:-- --

:-- ----

-

3 ---

--:-- --

:-- ----

-

4 ---

--:-- --

:-- ----

-

5 ---

--:-- --

:-- ----

-

6 ---

--:-- --

:-- ----

-

7 ---

--:-- --

:-- ----

-

8 ---

--:-- --

:-- ----

-

SPL

SAT-SUN

 

 

•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••

•••••••••••••

50