Other convenient functions

Power failure compensation circuit

The unit is equipped with an internal power failure com- pensation circuit. When the unit has been charged for 48 hours (full), the date, time, timer record settings, and menu settings are kept up to 1 month without power. The accuracy of the time will decline if the power plug is not connected to the wall outlet for and extensive pe- riod. When the unit is with out power for a long time it is recommended to check the current time setting.

Power failure reset recording

If there is a power failure during recording or when the MAIN switch is turned OFF, the recording will resume after the power is restored. If there is a power failure during timer recording, the recording will resume after the power is restored when within the set time period of the timer. For alarm recording, recording will stop even within the set recording time.

The playback video at the start position where re- cording is resumed after a power failure may be dis- turbed and the search function may not operate prop- erly.

Log function for when power failure occurs while the unit is in operation or the MAIN switch on the rear of the unit is turned OFF

In the event of power failure or the MAIN switch on the rear of the unit is turned OFF, up to 1000 times (includ- ing the time of failure and warning log displays as well as other warning items) are saved in the <WARNING LOG LIST> ( see page 62), and are displayed in red on the screen.

<INITIALIZATION>

ARCHIVE•COPY

>>ID4•ID5

HDD SETTING

NORMAL

BOOT UP SIZE

30S

POWER OFF

 

INITIALIZATION

 

ALL DATA WILL BE ERASED

WHEN PROCEED INITIALIZATION

2.Select “HDD SETTING” by turning the JOG dial, display the “MIRRORING” setting, and turn the SHUTTLE ring clockwise.

<INITIALIZATION>

ARCHIVE•COPY

ID4•ID5

>>HDD SETTING

MIRRORING

BOOT UP SIZE

30S

POWER OFF

 

INITIALIZATION

 

ALL DATA WILL BE ERASED

WHEN PROCEED INITIALIZATION

3.Select “INITIALIZATION” by turning the JOG dial, and turn the SHUTTLE ring clockwise.

The setting is made, and initialization commences.

Initialization deletes all data in the HDD.

RESET button

When pressing the RESET button on the rear of the unit with a ballpoint pen, etc., the unit is reset and the power turns off.

The menu settings, the current time and video data are kept even when resetting the unit.

HDD SETTING

On the unit, “MIRRORING” or “PARTITION” can be se-

lected for the HDD recording mode ( see page 22).

Setting ( default : “NORMAL” )

“NORMAL”, “MIRRORING”, “PARTITION”

MIRRORING

Saving the data on a second drive (mirroring) with the same capacity, reduces the risk of data loss due to an HDD crash.

1.Turn ON the MAIN switch on the rear of the unit, and wait until the ACCESS indicator goes off. Hold down the REC/STOP button, and press the POWER button on the front of the unit.

The <INITIALIZATION> screen is displayed.

•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••