Other convenient functions (continued)

PARTITION/PARTITION SIZE

PARTITION mode only uses the internal HDD, and pe- ripheral recording device HDD’s. PARTITION mode des- ignates the area inside the HDD that is specified as each HDD’s sub-device capacity for Alarm recording. This independent partition inside the HDD allows to keep the data of alarm recording.

1.Turn ON the MAIN switch on the rear of the unit, and wait until the ACCESS indicator goes off. Hold down the REC/STOP button, and press the POWER button on the front of the unit.

The <INITIALIZATION> screen is displayed.

2.Select “HDD SETTING” by turning the JOG dial, display “PARTITION”, and turn the SHUTTLE ring clockwise.

The “PARTITION SIZE” setting appears on the <INITIALIZATION> screen.

<INITIALIZATION>

ARCHIVE•COPY

ID4•ID5

>>HDD SETTING

PARTITION

PARTITION SIZE

10%

BOOT UP DELAY

30S

POWER OFF

 

INITIALIZATION

 

16 1.563P

STD

1.563P

STD

PRE ALARM REC

( S )

S

<ESTD REC>

 

SHUTTLE<<:BACK

 

D H M

%

4.Select “INITIALIZATION” by turning the JOG dial, and turn the SHUTTLE ring clockwise.

The setting is made, and initialization commences.

Initialization deletes all data in the HDD.

ALL DATA WILL BE ERASED

WHEN PROCEED INITIALIZATION

3.Display the desired device capacity, and turn the SHUTTLE ring clockwise.

The setting is made.

Setting of “PARTITION SIZE” ( default : 10% )

10%, 20%, 30%, 40%, 50%, 60%, 70%, 80%, 90%

The normal recording area is referred to as “MAIN”, and the alarm recording area (PARTITION area) is re- ferred to as “SUB”.

The storage area in MAIN HDD set in “PARTITION” is displayed with the percentage(%) and the record- able time of that storage area is displayed in “<ESTD REC>”.

Points to be aware of regarding PARTITION mode

Either “MAIN” or “SUB” can be selected for archive/copy.

Playback, search, information display, REMAIN HDD, MODE OUT, CALL OUT, and data delete functions are performed independently for “MAIN” and “SUB”.

When “HDD REPEAT REC SUB” is set to “OFF”, and all memory in SUB HDD is used, the recording stops. Switch “HDD REPEAT REC SUB” to “ON” or delete data in SUB HDD to restart recording.

Archive data is transmitted in 1MB units. The archive of up to 1MB of the latest data may be delayed. Beware when changing the archive device.

When at the time of “ALARM” use an alarm signal enters to a camera number not set for normal recording, pre-alarm recording may not be performed in some cases.

•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••

•••••••••••••