3.Turn the JOG dial until the cursor is next to “CAPACITY REMAIN” and turn the SHUTTLE ring to flash the
•The
<REAR | TERMINAL> | |
MODE | OUT | PLAY |
CAPACITY | REMAIN | |
|
|
|
4.Turn SHUTTLE ring and JOG dial to show
By turning the JOG dial, the sub- item of CAPACITY REMAIN shown on the menu will
be changed as follows:
HDDARCNONE
By turning the JOG dial, the sub- item of CAPACITY REMAIN shown on the menu will
be changed as follows:
10% 15% 20% 30%40%
8% 6% 4%2% 50%
5.Turn the SHUTTLE ring to the left or press the SET UP button.
♦CALL OUT setting
With this setting, the signal from CALL OUT terminal can be emitted externally to indicate the warning given from this unit. The signal is emitted from the CALL OUT terminal when the remaining storage capacity of main HDD reaches the preset amount. Likewise, the remaining storage capacity of archive medium can be set.The CALL OUT signal is also emitted when HDD FULL in the <INITIAL SET UP> menu is set to “STOP”.
INFORMATION
For more on the relation between Warning Display and CALL OUT emission, please refer to page 75. When the emission parameter in CALL OUT is set to “Yes”, the warning display will appear unconditionally; when the parameter is set to “Selectable”, the unit can be made to emit a CALL OUT signal through additional settings. For exam- ple, when the BUZZER setting on the <REAR TER- MINAL> menu is set to “KEY”, the unit will sound a buzzer when the remaining amount on the hard disk has reached the figure specified on the <CALL OUT> menu.
Example: Setting CALL OUT of main HDD to “10%” (the default setting is “FULL”) and CALL OUT of archive medium to “20%” (the default is “NONE”).
1.Press the SET UP button to display the <MENU SETTING> menu.
2.Turn the JOG dial to move the cursor to REAR TERMINAL then turn the SHUTTLE ring to the right.
• The <REAR TERMINAL> menu will appear.
<REAR | TERMINAL> | REMAIN |
@MODE | OUT |
CAPACITY REMAIN
CALL OUT
3.Turn the JOG dial until the cursor is next to “CALL OUT” and turn the SHUTTLE ring to the right to show the <CALL OUT> menu.
<CALL OUT>
@HDD(ID:0~3) FULL
ARCHIVE(ID:4) NONE
4.Confirm that the cursor is next to “HDD” and turn the SHUTTLE ring to the right to flash the
<CALL OUT>
@HDD(ID:0~3) FULL
ARCHIVE(ID:4) NONE
5.Turn the JOG dial to flash “10%” and turn the SHUTTLE ring to the right to complete setting.
<CALL OUT>
@HDD(ID:0~3) 10%
ARCHIVE(ID:4) NONE
By turning the JOG dial, the item of CALL OUT shown on the screen switches as
shown below:
FULL 2%4%6%8%10% NONE50%40%30%20%15%
“NONE”: No signal is emitted from the CALL OUT terminal.
6.Turn the JOG dial until the cursor is next to “ARCHIVE” and turn the SHUTTLE ring to the right.
•The
<CALL OUT>
HDD(ID:0~3) FULL
@ARCHIVE(ID:4) NONE
7.Turn the JOG dial to flash “20%” and turn the SHUTTLE ring to the right.
•The
<CALL OUT>
HDD(ID:0~3) 10%
@ARCHIVE(ID:4) 20%
8.Turn the SHUTTLE ring to the left or press the SET UP button.