3.Turn the JOG dial until the cursor is next to “CAPACITY REMAIN” and turn the SHUTTLE ring to flash the sub-item.

The sub-item of the device will start flashing first. Choose the device you want to set by using the JOG dial and SHUTTLE ring. Then sub-item of the remain will start flashing.

<REAR

TERMINAL>￿

MODE

OUT

PLAY￿

CAPACITY

REMAIN HDD-10%

 

 

 

4.Turn SHUTTLE ring and JOG dial to show “HDD-50%” and turn the SHUTTLE ring to the right to complete setting.

By turning the JOG dial, the sub- item of CAPACITY REMAIN shown on the menu will

be changed as follows:

HDDARCNONE

By turning the JOG dial, the sub- item of CAPACITY REMAIN shown on the menu will

be changed as follows:

10% 15% 20% 30%40%

8% 6% 4%2% 50%

5.Turn the SHUTTLE ring to the left or press the SET UP button.

CALL OUT setting

With this setting, the signal from CALL OUT terminal can be emitted externally to indicate the warning given from this unit. The signal is emitted from the CALL OUT terminal when the remaining storage capacity of main HDD reaches the preset amount. Likewise, the remaining storage capacity of archive medium can be set.The CALL OUT signal is also emitted when HDD FULL in the <INITIAL SET UP> menu is set to “STOP”.

INFORMATION

For more on the relation between Warning Display and CALL OUT emission, please refer to page 75. When the emission parameter in CALL OUT is set to “Yes”, the warning display will appear unconditionally; when the parameter is set to “Selectable”, the unit can be made to emit a CALL OUT signal through additional settings. For exam- ple, when the BUZZER setting on the <REAR TER- MINAL> menu is set to “KEY”, the unit will sound a buzzer when the remaining amount on the hard disk has reached the figure specified on the <CALL OUT> menu.

Example: Setting CALL OUT of main HDD to “10%” (the default setting is “FULL”) and CALL OUT of archive medium to “20%” (the default is “NONE”).

1.Press the SET UP button to display the <MENU SETTING> menu.

2.Turn the JOG dial to move the cursor to REAR TERMINAL then turn the SHUTTLE ring to the right.

• The <REAR TERMINAL> menu will appear.

<REAR

TERMINAL>￿

REMAIN￿

@MODE

OUT

CAPACITY REMAIN HDD-10%

￿

CALL OUT

3.Turn the JOG dial until the cursor is next to “CALL OUT” and turn the SHUTTLE ring to the right to show the <CALL OUT> menu.

<CALL OUT>￿

@HDD(ID:0~3) FULL￿

ARCHIVE(ID:4) NONE

4.Confirm that the cursor is next to “HDD” and turn the SHUTTLE ring to the right to flash the sub-item.

<CALL OUT>￿

@HDD(ID:0~3) FULL￿

ARCHIVE(ID:4) NONE

5.Turn the JOG dial to flash “10%” and turn the SHUTTLE ring to the right to complete setting.

<CALL OUT>￿

@HDD(ID:0~3) 10%￿

ARCHIVE(ID:4) NONE

By turning the JOG dial, the item of CALL OUT shown on the screen switches as

shown below:

FULL 2%4%6%8%10% NONE50%40%30%20%15%

“NONE”: No signal is emitted from the CALL OUT terminal.

6.Turn the JOG dial until the cursor is next to “ARCHIVE” and turn the SHUTTLE ring to the right.

The sub-item will start flashing.

<CALL OUT>￿

HDD(ID:0~3) FULL￿

@ARCHIVE(ID:4) NONE

7.Turn the JOG dial to flash “20%” and turn the SHUTTLE ring to the right.

The sub-item stops flashing.

<CALL OUT>￿

HDD(ID:0~3) 10%

@ARCHIVE(ID:4) 20%

8.Turn the SHUTTLE ring to the left or press the SET UP button.