Various recording settings (continued)

4.Turn the JOG dial to move the cursor to A-REC DURATION and turn the SHTTLE ring to the right.

The sub-item will start flashing.

5.Turn the JOG dial to display “15S” and turn the SHUTTLE ring to the right to define the setting.

The sub-item will stop flashing. Check that the A-REC DURATION is entered correctly.

@A-REC

DURATION￿

 

1M￿

A-REC P.GRADE￿

HIGH￿

PRE A-REC

OFF

@A-REC DURATION￿

 

 

15S￿

A-REC P.GRADE￿

HIGH￿

PRE A-REC

OFF

By turning the JOG dial, the sub- item of the A-REC DURATION shown on the menu

will be changed as follows:

1M2M5M10M 45S30S15S MAN

6.Turn the JOG dial to move the cursor to A-REC P.GRADE and turn the SHUTTLE ring to the right.

A-REC DURATION￿

15S￿

@A-REC P.GRADE￿

HIGH￿

PRE A-REC

OFF

The recording interval settings for normal recording have to be set on the same menu. For details of

settings for recordings, please refer to page 33.

7.Turn the JOG dial to flash “STANDARD” and turn the SHUTTLE ring to the right to enter the setting.

The sub-item will stop flashing. Check that the A-REC P.GRADE is entered correctly.

A-REC DURATION￿

15S￿

@A-REC P.GRADE￿ STANDARD￿

PRE A-REC

OFF

By turning the JOG dial, the sub- item of the A-REC P.GRADE shown on the menu

will be changed as follows:

HIGHSUPERIORLOW

STANDARDBASIC

8.Turn the SHUTTLE ring to the left or press the SET UP button.

Please refer to “Setting of Alarm recording cam- era” on page 39 for details of the cameras to be

activated when alarm recording is activated.

INFORMATION

Please refer to “Alarm Recording operation” on page 45 for details of the alarm re-

cording.

Pre-alarm recording setting

During alarm recording, it is possible to record the picture several seconds before the signal is input in to the ALARM IN terminal.

The USER KEY can be used to set the pre-alarm recording on/off. Refer to page 25 for details.

Example: Set the PRE A-REC to “LONG” (the default setting is “OFF”).

1.Make settings for A-REC P.GRADE, A-REC INTERVAL and A-REC DURATION as shown on page 33 and this page.

A-REC DURATION￿

15S￿

@A-REC P.GRADE￿ STANDARD￿

PRE A-REC

OFF

2.Turn the JOG dial to move the cursor to PRE A-REC and turn the SHUTTLE ring to the right to flash the sub-item.

A-REC DURATION￿

15S￿

A-REC P.GRADE￿ STANDARD￿

@PRE A-REC

OFF

3.Turn the JOG dial to flash LONG, and turn the SHUTTLE ring to the right. The unit will be in stand-by mode for the

Pre-alarm recording.

PRE ALARM REC indicator on the front of the unit will start illuminating.

A-REC DURATION￿

15S￿

A-REC P.GRADE￿ STANDARD￿

@PRE A-REC

LONG

By turning the JOG dial, the sub-item of PRE A- REC will be changed as follows:

OFFSHORT

LONGMIDDLE

4.Ground the ALARM IN terminal.

The unit will start alarm recording.

The duration of recording before the ALARM IN terminal is triggered depends on the A-REC INTER-

VAL, A-REC P.GRADE, and PRE A-REC settings. Please refer to “Pre-alarm Recording” on page 46 for details.

INFORMATION

To activate pre-alarm recording on Timer programmes, please refer to “Pre-alarm Re-

cording” on page 46.

Following the end of Pre-alarm recording, the regular value of the Alarm Recording settings returns to the value set in the A-REC P.GRADE, A-REC INTERVAL, and A-REC DURATION settings.

Alarm input (ALARM IN signal)

Recording

Pre - alarm

 

Alarm

Mode

recording

 

recording

Effective

 

 

 

 

 

LONG/MIDDLE/SHORT of

 

A-REC P.GRADE/

recording

 

PRE A-REC

 

A-REC INTERVAL/

setting

 

A-REC P.GRADE/

 

A-REC DURATION

 

 

 

A-REC INTERVAL

 

 

 

•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••

••••••••••••

34