INFORMATION
PROGRAM> menu. Once these settings are en- tered, the system can be switched between regular and
4) Set the Timer Program’s operational mode to P1.
Upon completing the above settings, press the TIMER REC button. The unit will be in timer recording
■Operation example 2: Endless Repeat recording
Copies and backups of up to 3 days’ volume of recorded data can be made when the unit is running in continuous recording mode. (Refer to page 52 for details on copying.)
System configuration
Example of a system using the following peripherals:
•9 connected video cameras
•Archive device connected to ID4 or copying device connected to ID5
•Monitor
Monitor | (Up to 9 cameras) |
• • • |
ID4: archive device
ID5: copy device
Images input by each of the connected cameras are recorded 24 hours a day.
•Set REC INTERVAL to “1.56F”.
•Set REC P.GRADE to “STANDARD”.
•Set AUDIO RECORDING to “ON”.
<RECORDING SET UP>
@REC | INTERVAL |
| 1.56F |
REC | P.GRADE | STANDARD | |
AUDIO RECORDING | ON | ||
<ESTD TIME> |
| 167H27M |
• Set HDD FULL to “REPEAT”.
<INITIAL SET UP>
TIME DATE ADJUST ARCHIVE OVERWRITE OFF
@HDD | FULL | REPEAT |
HDD | PB REPEAT | OFF |
Upon completing the above settings, press the unit’s REC button to initiate continuous recording operation.
♦Making copies as needed
To copy segments of recorded data while the unit is running in continuous recording mode, make the following adjustments:
•Change the automatic copy range setting to MANUAL, and enter the desired
♦Making backups as needed
To make backups, while the unit is running in continuous recording mode, of portions of the total data stored in the unit’s hard disk, load the appropriate medium into the archive device and press the ARCHIVE button.
■Operation example 3
The number of video cameras can differ between operational modes A and B, and you may specify which set of cameras goes into effect at what time and/or on which day(s). Recording intervals can be reduced when the number of operational cameras is large, and recording intervals can be increased when using fewer cameras.
System configuration
Settings are entered so that the backups are created every Monday morning between 00:00 and 05:00. To facilitate the exchange of the storage medium after the backup has been completed, AUTO EJECT is set to “ON”. Refer to
Cameras in CAMERA USAGE A are set to operate from 08:00 to 15:00 on Monday through Friday. Cameras in CAMERA USAGE B are set to operate from 15:00 to 20:00 on these same days.
Cameras in CAMERA USAGE B are set to operate from 08:00 to 17:00 on Saturday and Sunday.The overall schedule is as shown in the following chart.
00 : 00 | 05 : 00 |
|
|
|
|
| ||
Monday |
|
|
|
|
|
|
|
|
| Archive |
|
|
|
|
|
| |
|
| replace archive medium | ||||||
|
| 08 : 00 | 15 : 00 |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| CAMERA USAGE A |
|
| ||
|
|
|
|
| 20 : 00 | |||
|
|
|
|
|
|
|
|
|
Monday to Friday |
| CAMERA USAGE B |
| |||||
|
| 08 : 00 | 17 : 00 |
| ||||
|
|
|
|
|
|
| ||
Saturday and Sunday |
|
|
|
|
| |||
| CAMERA USAGE B |
|
|
Settings
1)Camera settings are made as follows. (Refer to page 38 for details on the “Camera usage setting” screen.)
•Set cameras #1 through #9 to operational mode A.
•Set cameras #1, #2, #3, #8, and #9 to operational mode B.
2)Recording picture grade (REC P.GRADE) is set to “STANDARD”.
3)Settings for TIMER PROGRAM are made as follows.
•Designate Monday to Friday as the days of operation (SPECIAL DW). Then, in Program #1, set the action (MODE) to “A– 1F” for 08:00 to 15:00 on the designated days(SPL).
•In Program #2, set the action to “B– 1F” for 15:00 to 20:00 on the designated days.
•In Program #3, set the action to “B– 1F” for 08:00 to 17:00 on Saturday.
•In Program #4, set the action to “B– 1F” for 08:00 to 17:00 on Sunday.
•In Program #5, set the action to BACKUP for Sunday’s start- time of 00:00 to
Upon completing the above settings, press the unit’s TIMER REC button to initiate Timer operation.
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• | •••••••••••• | • |
42