I/O terminals

GND terminals

The ground terminals for Input/Output terminals.

CLOCK ADJ terminal

Input terminal to set the present time display. Time display is adjusted to the nearest hour (00 minutes 00 sec- onds) when this terminal receives the CLOCK ADJ sig- nal.

REC terminal

Input terminal to start recording. Also use for one-shot recording.

POWER ON terminal

Input terminal to turn on this unit through a peripheral device.

POWER OFF terminal

Input terminal to turn off this unit through a peripheral device.

ALARM OUT terminal

Output terminal to indicate that the alarm recording is in process.

MODE OUT terminal

Output terminal to indicate the unit’s current mode. Select the unit’s condition by MODE OUT setting in the <REAR TERMINAL> menu.

CALL OUT terminal / CALL OUT GND terminal

This is the ISOLATION output terminal. (Refer to page 76.) Output terminal and its GND terminal to indicate the information such as “HDD FULL”. Select the information by CALL OUT setting in the <REAR TERMINAL> menu.

DC 5V OUT terminal

This terminal is for direct current voltage output. The maximum electric current is 30mA.

*#1

If the power cord has no earth terminal, consult your dealer to replace the code (with charge). Do not connect the earth terminal of a plug to gas pipe, water pipe, lightning rod and so on.

••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••