Warnings and CALL OUT output
■Warnings and their appropriate countermeasures
Options in the CALL OUT options column:
•Selectable: CALL OUT output can be
•Yes: a CALL OUT signal is emitted without prior selection of this function using the menu.
•None: no CALL OUT signal is emitted, but a warning indicator will appear on screen.
Warning | Status |
| Countermeasure |
| Canceling | CALL OUT | Reference | ||
|
|
|
|
|
| the warning | output |
| |
| The internal hard disk drive | • When the warning is canceled, the unit | Press the |
| 46 | ||||
HDD FULL | is full when either “STOP” | or will start |
| WARNING | Selectable |
| |||
“REC•STANDBY” has been |
| remaining in the hard disk drive. |
|
| |||||
|
|
| RESET button. |
| 26,27,30 | ||||
| selected in “HDD REPEAT”. | • Archive or copy data as necessary. |
|
| |||||
|
|
|
| ||||||
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |
| The storage capacity of the |
|
|
|
| Press the |
|
| |
| hard disk drive is approach | - |
|
|
|
| |||
HDD NEAR END |
|
| WARNING |
| 26 | ||||
ing the value entered into |
| • Archive or copy data as necessary. |
| Selectable | |||||
|
| RESET button. | |||||||
| the HDD capacity setting. |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| ||
ARCHIVE FULL | The storage medium in the | • Replace the medium in the backup |
| Press the | Selectable | 26,27 | |||
backup recording device is |
| recording device. |
|
| WARNING | ||||
| full. |
|
|
| RESET button. |
|
| ||
|
|
|
|
|
|
| |||
| The limit of the archive | • Replace the medium in the backup |
| Press the |
|
| |||
ARCHIVE NEAR END | medium's storage capacity |
| WARNING | Selectable | 26,27 | ||||
| is being reached. |
| recording device. |
|
| RESET button. |
|
| |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| |||
COPY OVERTAKE |
|
| • If you do not wish to have the data over- |
|
| ||||
| written, stop recording. |
|
| Press the |
|
| |||
ERROR | • Change the settings for recording | Yes | |||||||
ARCHIVE OVERTAKE | was in Repeat mode. |
| val and image quality(More. | specifically, | RESET button. |
|
| ||
ERROR |
|
| lengthen intervals and lowre image quality.) |
|
|
| |||
|
|
|
|
|
|
|
|
| |
COPY NEAR | The HDD is in Repeat mode, |
| • If you do not wish to have the data over- |
|
| ||||
and data which has not been |
|
|
| ||||||
OVERTAKE |
| written, stop recording. |
|
|
|
|
| ||
backed up will be |
|
|
| Press the | Yes | ||||
|
|
|
| ||||||
ARCHIVE NEAR | (The amount of time remaining | • Change the settings for recording | |||||||
| |||||||||
OVERTAKE | before the unit begins over- |
| val and image quality(More. | specifically, | RESET button. |
|
| ||
| writing is approx. 5% of the |
| lengthen intervals and lowre image quality.) |
|
|
| |||
| time indicated as the possible |
|
|
|
|
|
|
| |
| recording duration.) |
|
|
|
|
|
|
| |
| When using the copy or |
|
|
|
|
|
|
| |
COPY SIZE ERROR | restore functions, either the |
|
|
| Press the |
|
| ||
amount of data to be | • Reset the range of backup or copying. |
|
| ||||||
ARCHIVE SIZE ERROR | transferred exceeds the | WARNING | Yes | ||||||
• Replace the archive/copy medium. | RESET button. | ||||||||
RESTORE SIZE ERROR |
|
|
|
| |||||
limits of the storage medium, |
|
|
|
| |||||
| or there is no data to be |
|
|
|
|
|
| ||
| copied. |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| ||
|
|
| • Check the storage medium in the RDD | Press the |
|
| |||
COPY CHECK MEDIA | An error has occurred in | or DDS device. (Insert medium if there |
|
| |||||
is none. If medium is present and you | WARNING |
|
| ||||||
ARCHIVE CHECK MEDIA | either the RDD device or | Yes | |||||||
with to use it, undo the | |||||||||
RESTORE CHECK MEDIA | the DDS device. | If medium is present and you do not |
|
|
| ||||
|
|
| wish to use it, replace the medium.) |
|
|
| |||
|
|
|
|
|
|
|
|
| |
|
|
| • Check whether the unit and camera are | • Either turn off |
|
| |||
NO SIGNAL |
|
| recording or, if the |
|
| ||||
|
| properly connected, and that electricity |
|
| |||||
Visual signal was absent | visual signal has |
|
| ||||||
(1 2 3 4 5 6 7 8 9) |
|
| |||||||
for over 5 seconds during | is on. |
|
| been restored, | Yes | 17,38 | |||
| • Check whether the visual signal is | ||||||||
[The warning will | recording. | cancel the warning |
|
| |||||
being properly outputted. |
|
|
|
| |||||
indicate the number |
|
|
|
| • Press the |
|
| ||
|
| • Check whether the unit’s camera |
|
| |||||
of the |
|
| WARNING RESET |
|
| ||||
| setting is set to an empty channel. |
|
| ||||||
camera.] |
|
| button. |
|
| ||||
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| |
SYSTEM ERROR |
|
| • Confirm that the SCSI cable is properly |
|
|
| |||
REC SYSTEM ERROR |
|
| Press the |
|
| ||||
SCSI connection error or | connected. |
|
|
|
| ||||
COPY SYSTEM ERROR |
|
| WARNING | Yes | 17 | ||||
system malfunction. | • Restart operation. |
|
| ||||||
ARCHIVE SYSTEM ERROR |
|
| RESET button. |
|
| ||||
• Inspect the HDD/archive/copy device. |
|
| |||||||
RESTORE SYSTEM ERROR |
|
|
|
|
| ||||
|
|
|
|
|
|
|
| ||
COPY R/W ERROR | A |
|
| Press the |
| 18 | |||
ARCHIVE R/W ERROR | during backup or copying. • Inspect the archive/copy device. | WARNING | None | ||||||
RESTORE R/W ERROR |
|
|
|
|
| RESET button. |
|
| |
|
|
|
|
|
|
|
|
|
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• | Warnings and CALL OUT output |
ENGLISH