Various settings (continued)
♦Buzzer setting
You can set to sound the buzzer when the remaining storage capacity of the Hard Disk Drive reaches the amount set in CAPACITY REMAIN setting on the <REAR TERMI- NAL> menu. In addition to the above setting of CALL OUT setting section, it is also possible to sound the buzzer when other errors occur.
To sound the buzzer when the remaining storage capacity reaches the preset amount.
1)Select “REMAIN” of BUZZER in the <REAR TER- MINAL > menu.
2)Set the device and its remaining storage capac- ity of CAPACITY REMAIN in the <REAR TERMI- NAL> menu.
To sound the buzzer when the remaining storage capacity reaches the preset amount or other error occurs.
1)Select “WRNG” of BUZZER in the <REAR TER- MINAL> menu.
2)Set the device and its remaining storage capac- ity of CAPACITY REMAIN in the <REAR TERMI- NAL> menu.
Example: Setting BUZZER to “REMAIN” (the default setting is “KEY”).
1.Display the <MENU SETTING> menu and turn the JOG dial until the cursor is next to REAR TERMINAL. Then turn the SHUTTLE ring to the right.
•The <REAR TERMINAL> menu appears.
<REAR | TERMINAL> | REMAIN |
|
@MODE | OUT |
| |
CAPACITY REMAIN |
| ||
OUT |
|
| |
CALL |
|
|
2.Turn the JOG dial until the cursor is next to BUZZER and turn the SHUTTLE ring to the right to flash the
CALL OUT
@BUZZERKEY
3.Turn the JOG dial to show “REMAIN” and turn the SHUTTLE ring to the right to complete setting.
•The
CALL OUT
@BUZZERREMAIN
By turning the JOG dial, the item of BUZZER shown on the screen switches as shown below.
KEYWRNGREMAINOFF
“KEY”: The buzzer sounds when any button is pressed, or JOG dial or SHUTTLE ring is turned.
“WRNG”: The buzzer sounds when a warning oc- curs. Refer to page 75, “Warnings and CALL OUT output”, for details.
“REMAIN”: The buzzer sounds when the remaining storage capacity of main HDD and ARCHIVE reaches the preset amount selected in CAPACITY REMAIN. Press WARNING RESET button to stop the buzzer.
“OFF”: The buzzer does not sound.
4.Turn the SHUTTLE ring to the left or press the SET UP button.
♦
This unit can be connected with a personal computer via the
It is possible to record characters with images.
■Service menu setting
In the <SERVICE> menu, you can see the power failure time, reset the Archive Pointer and initialize menus.
♦Power Failure list
The list of time when the power failure occurred is avail- able.
Example: Displaying POWER FAILURE list.
Up to 50 power failure start times are shown on the list. If more than 50 times, the last 50 start times
are shown.
1.Display the <MENU SETTING > menu and turn the JOG dial until the cursor is next to SERVICE. Turn the SHUTTLE ring to the right.
•The <SERVICE> menu appears.
<SERVICE> |
|
@POWER FAILURE | OFF |
ARCHIVE POINT RESET | |
MENU INITIALIZE | OFF |
2.Check that the cursor is next to POWER FAILURE and turn the SHUTTLE ring to the right.
<POWER FAILURE>
No. DATE TIME INFO. 02
•The <POWER FAILURE> list appears on the screen.
•The number of times, the date and the time when the power failure occurred are given on the list.
To reset the power failure start time, press the WARNING RESET button when the <POWER FAIL-
URE> list is shown on the screen.
3.Turn the SHUTTLE ring to the left or press the SET UP button.
♦Resetting the Archive Pointer
This unit writes down the Archive Pointer Glossary where the archive stops. In the next archive, it starts from the point where the Archive Pointer is placed. If you want to reset this Archive Pointer, follow the steps shown below.
1.Press the SET UP button to display the <MENU SETTING> menu.
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• | •••••••••••• | • |
28