25F￿ HIGH￿ OFF￿ 9H11M

Various recording settings

Various recording settings

This Unit has many settings for various recordings. You have to make settings on different pages for normal recording and timer recording. Please refer to the table below for details. If the channel which is to be operated on <CAMERA SETTING> is not set, the warning will appear.

Recording

 

 

Recording by setting manually

 

 

 

Timer recording

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting

 

Normal recording

Page

 

Alarm recording

Page

 

Normal recording

Page

 

 

Alarm recording

Page

 

REC P.GRADE in

 

 

 

 

 

 

A-REC P.GRADE in

 

 

 

 

REC P.GRADE in

 

 

 

A-REC P.GRADE in

 

 

 

 

Recording

<RECORDING SET UP>

 

 

 

 

<RECORDING SET UP>

 

<RECORDING SET UP>

 

<RECORDING SET UP>

 

 

 

 

 

 

 

page

 

 

 

 

 

This

 

 

 

 

page

 

 

 

 

 

 

This

picture grade

 

<RECORDING SET UP>￿

 

 

 

A-REC DURATION￿

1M￿

 

 

 

<RECORDING SET UP>￿

 

 

 

A-REC DURATION￿

1M￿

 

 

 

25F￿

 

13

 

 

 

 

 

 

13

 

 

 

 

 

 

REC INTERVAL￿

 

 

 

A-REC P.GRADE￿

HIGH￿

 

 

page

 

REC INTERVAL￿

25F￿

 

 

 

A-REC P.GRADE￿

HIGH￿

 

 

page

 

 

REC P.GRADE￿

HIGH￿

 

 

 

 

 

PRE A-REC￿

OFF￿

 

 

 

 

REC P.GRADE￿

HIGH￿

 

 

 

 

PRE A-REC￿

OFF￿

 

 

 

 

 

AUDIO RECORDING￿

OFF￿

 

 

 

 

 

ONESHOT¥FIELD

1

 

 

 

 

AUDIO RECORDING￿

OFF￿

 

 

 

 

ONESHOT¥FIELD

1

 

 

 

 

 

￿

￿

 

 

 

 

 

 

 

 

 

 

 

￿

￿

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REC INTERVAL in

 

 

 

 

 

 

A-REC INTERVAL in

 

MODE setting in

 

 

 

A-REC INTERVAL in

 

Recording

<RECORDING SET UP>

page

 

<RECORDING SET UP>

This

<TIMER PROGRAM>

page

<RECORDING SET UP>

This

interval

 

<RECORDING SET UP>￿

25F￿

 

13

 

 

A-REC INTERVAL￿

25F￿

 

 

page

 

<TIMER PROGRAM>￿

MODE￿

 

43

 

 

A-REC INTERVAL￿

25F￿

 

 

page

 

 

REC INTERVAL￿

 

 

 

 

 

A-REC DURATION￿

1M￿

 

 

 

 

DW START END

 

 

 

 

A-REC DURATION￿

1M￿

 

 

 

 

 

REC P.GRADE￿

HIGH￿

 

 

 

 

 

A-REC P.GRADE￿

HIGH￿

 

 

 

 

WED 09:30 10:00 A-25F￿

 

 

 

 

A-REC P.GRADE￿

HIGH￿

 

 

 

 

 

AUDIO RECORDING￿

OFF￿

 

 

 

 

 

PRE A-REC￿

OFF￿

 

 

 

 

2 --- --:-- --:-- ------

 

 

 

 

PRE A-REC￿

OFF￿

 

 

 

 

 

￿

￿

 

 

 

 

 

￿

￿

 

 

 

 

 

 

 

 

 

 

￿

￿

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A-REC DURATION in

 

START and END time in

 

 

A-REC DURATION in

 

Recording

 

 

 

 

 

 

 

 

 

 

<RECORDING SET UP>

This

<TIMER PROGRAM>

page

 

<RECORDING SET UP>

This

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

duration

 

 

 

 

 

 

 

 

 

 

A-REC INTERVAL￿

25F￿

 

 

page

 

<TIMER PROGRAM>￿

MODE￿

 

43

 

 

A-REC INTERVAL￿

25F￿

 

page

 

 

 

 

 

 

 

 

 

 

A-REC DURATION￿

1M￿

 

 

 

DW START END

 

 

 

A-REC DURATION￿

1M￿

 

 

 

 

 

 

 

 

 

 

 

 

A-REC P.GRADE￿

HIGH￿

 

 

 

 

WED 09:30 10:00 A-25F￿

 

 

 

 

A-REC P.GRADE￿

HIGH￿

 

 

 

 

 

 

 

 

 

 

 

 

 

PRE A-REC￿

OFF￿

 

 

 

 

2 --- --:-- --:-- ------

 

 

 

 

PRE A-REC￿

OFF￿

 

 

 

 

 

 

 

 

 

 

 

 

 

￿

￿

 

 

 

 

 

 

 

 

 

 

￿

￿

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Selected CAMERA USAGE

 

 

 

Selected ALARM REC CH.

 

Selected CAMERA USAGE

 

Selected ALARM REC CH.

 

 

pattern on

 

 

 

 

 

setting on

 

 

 

 

pattern on MODE setting

 

setting on

 

 

 

 

 

<MPX FUNCTIONS>

 

 

 

 

 

<MPX FUNCTIONS>

 

of <TIMER PROGRAM>

 

<MPX FUNCTIONS>

 

Recording

 

 

 

 

 

 

page

 

 

 

 

 

page

 

 

 

 

page

 

 

 

 

 

 

page

camera channel

 

<MPX FUNCTIONS>￿

A

 

38

 

 

<MPX FUNCTIONS>￿

A￿

 

 

39

 

<TIMER PROGRAM>￿

MODE￿

 

43

 

 

<MPX FUNCTIONS>￿

A￿

 

39

 

CAMERA USAGE￿

 

 

 

 

 

CAMERA USAGE￿

 

 

 

DW START END

 

 

 

 

CAMERA USAGE￿

 

 

(CH)

 

CAMERA SETTING￿

 

 

 

 

 

 

CAMERA SETTING￿

￿

 

 

 

WED 09:30 10:00 A-25F￿

 

 

 

 

CAMERA SETTING￿

￿

 

 

 

SPLIT SCREEN SETTING

 

 

 

 

 

SPLIT SCREEN SETTING￿ ￿

 

 

 

2 --- --:-- --:-- ------

 

 

 

 

SPLIT SCREEN SETTING￿ ￿

 

 

 

 

 

 

 

 

 

 

 

 

 

SPLIT P.GRADE￿

SHARP￿

 

 

 

 

 

 

 

 

 

SPLIT P.GRADE￿

SHARP￿

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SEQUENTIAL￿

￿

 

 

 

 

 

 

 

 

 

SEQUENTIAL￿

￿

 

 

 

 

 

 

 

 

 

 

 

 

 

ALARM REC CH.￿

SEP.￿

 

 

 

 

 

 

 

 

 

ALARM REC CH.￿

ALL￿

 

 

 

 

 

 

 

 

 

 

 

 

 

CH. TITLE

CH.NO

 

 

 

 

 

 

 

 

 

CH. TITLE

CH.NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENGLISH

Recording Interval Setting

For details please refer to “Setting the recording interval” on page 13.

Audio Recording

For details please refer to “Using the audio recording” on page 14.

Estimated recording time <ESTD TIME>

For details please refer to “Changing the recording picture grade” on page 13.

Recording picture grade setting

For details please refer to “Changing the recording picture grade” on page 13.

Alarm recording interval, Alarm recording duration and Alarm recording picture grade setting

When the ALARM IN terminal is triggered by an alarm sen- sor, the uint will switch to its preset recording intervals, and can record at both the regular recording intervals and an- other recording interval. In addition, settings can be made for the recording intervals and image quality used when the ALARM IN terminal is triggered.

Example: Setting the A-REC INTERVAL to “12.5F” (the default setting is “25F”). Set the A-REC DURATION to “15S” (the default setting is “1M”). Set the A-REC P.GRADE to “STANDARD” (the default setting is “HIGH”).

1.Display the <MENU SETTING> menu. Turn the JOG dial to RECORDING SET UP then turn the SHUTTLE ring to the right.

The <RECORDING SET UP> menu will appear.

<RECORDING SET UP>￿ @REC INTERVAL￿ REC P.GRADE￿ AUDIO RECORDING￿ <ESTD TIME>

2.Turn the JOG dial to move the cursor to A-REC INTERVAL and turn the SUTTLE ring to the right.

The sub-item will start flashing.

A-REC INTERVAL￿

25F￿

A-REC

DURATION￿

1M￿

A-REC

P.GRADE

HIGH

3.Turn the JOG dial to flash “12.5F” and turn the SHUTTLE ring to the right.

The sub-item stops flashing. Check that the A-REC INTERVAL is defined correctly.

A-REC INTERVAL￿

12.5F￿

A-REC DURATION￿

1M￿

A-REC P.GRADE

HIGH

••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••

Operations

33