Operation examples
♦Picture grade of sequential display
It is possible to set the image quality for
Example: Setting the sequential picture quality to “SOFT” (the default setting is “SHARP”).
1.Press the SET UP button to display the <MENU SETTING> menu.
2.Turn the JOG dial to move the cursor to MPX FUNCTIONS then turn the SHUTTLE ring to the right.
•The <MPX FUNCTIONS> will appear.
Settings
1)Camera settings are made as follows.
•Make the settings for the 9 cameras listed under column A in the <CAMERA SETTING> menu.
Operational cameras #1 through #9.
|
|
|
|
|
|
<CAMERA SETTING> |
| ||||
CH ABC | TITLE | ||||
@1 &&& | ENTRANCE........ | ||||
2 | &&- | ATM1............ | |||
3 | &&- | ATM2............ | |||
4 | &&- | COUNTER1........ | |||
5 | &&- | COUNTER2........ | |||
6 | COUNTER3........ | ||||
7 | VAULT........... | ||||
8 | EXIT............ | ||||
9 | PARKING......... |
|
ENGLISH
3.Turn the JOG dial to move the cursor to SPLIT P.GARDE then turn the SHUTTLE ring to the right to flash the
CAMERA SETTING
SPLIT SCREEN SETTING
@SPLIT P.GRADE | SHARP |
4.Turn the JOG dial to choose “SOFT” and turn the SHUTTLE ring to the right to fix setting.
•The
CAMERA SETTING
SPLIT SCREEN SETTING
@SPLIT P.GRADE | SOFT |
The number of cameras used in each of the operational modes A, B, C can be adjusted. Refer to page 38 for details.
The sequential display of the picture will get slower when more cameras are connected.
2)Recording settings are made as follows.
•Set REC INTERVAL to “1F”.
<RECORDING SET UP> @REC INTERVAL REC P.GRADE AUDIO RECORDING <ESTD TIME>
5.Turn the SHUTTLE ring to the right or press the SET UP button to finish setting.
■Operation example 1: Simultaneous Backup using the Timer
The Timer can be used for making weekly data backups when the unit is running in continuous recording mode.The unit will automatically eject the storage medium upon completion of the backup, and a new one may then be inserted into the machine.
System configuration
Example of a system using the following peripherals:
•9 connected video cameras
•Archive device connected to ID4
•Monitor
The capability to record continuously over a one- week period is dependent on the settings for record-
ing interval and recording picture grade. For details on the relationship between intervals and image quality, refer to “Audio recording time table” on pages 71.
•Set REC P.GRADE to “BASIC”.
•Set AUDIO RECORDING to “OFF”.
•Set HDD FULL to “REPEAT”.
<INITIAL SET UP>
TIME DATE ADJUST ARCHIVE OVERWRITE OFF
@HDD | FULL | REPEAT |
HDD | PB REPEAT | OFF |
• Set AUTO EJECT to “ON”.
Monitor
• • • (Up to 9 cameras)
ID4: archive device
HDD | FULL | STOP |
HDD | PB REPEAT | STOP |
@AUTO EJECT | ON | |
ARCHIVE DATA | ALL |
3) Enter the following settings under P1 on the TIMER PRO- |
GRAM menu: |
• In Timer programming number 2, set the action to BACKUP |
for Sunday’s start time of 00:00 to end time of 05:00. |
Images inputted by each of the connected cameras are recorded 24 hours a day, and the unit will make a backup of one week’s volume of image data while it continues to record current images. The unit records one frame per second when REC P.GRADE is set to “BASIC”, a recording rate of one frame per 9 seconds for each camera.
00 : 00 | 24 : 00 | ||
From Monday |
|
|
|
|
| ||
to Sunday |
|
| |
|
|
| |
00 : 00 | 05 : 00 |
|
Sunday Archive
Archive media auto eject
• Set the action to “A– 1F” for the daily start time of 00:00 to |
the next day’s end time of 00:00. (This setting activates, for |
all of the cameras in operational mode A, a recording rate of |
one frame per second.) |
<TIMER PROGRAM> | P1 |
DW START END | MODE |
@DAY 00:00¥00:00 AÐ 1F
2 SUN 00:00 05:00 ARC
3 ÐÐÐ ÐÐ:ÐÐ ÐÐ:ÐÐ ÐÐÐÐÐÐ
4 ÐÐÐ ÐÐ:ÐÐ ÐÐ:ÐÐ ÐÐÐÐÐÐ
The symbol “” will appear between the start- time and
that recording will continue until the following day.
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• | Operations |
41