Using the Timer (continued)

12.Press the TIMER REC button.

The TIMER REC indicator illminates.

If the current time is covered by a program, the unit will begin recording immediately.

If the current time is not covered by a program, the unit will turn the power off and go into stand-by mode.

Operation can be shut down completely by pressing the TIMER REC button once more.

“SKIP”: The SKIP setting can be used to temporarily shut down the recording. Recording will stop for the specified time frame, and the unit’s main power will automatically turn off.

“POWER”: Used when alarm recording is set with the Timer, this setting keeps the unit idle, but with the power on, during the specified time frame.

“ARCHIVE”: This setting is used for making backups of data stored in the unit’s hard disk drive.

Estimating the possible recording during when using the Timer

Please note when using the Timer that there may be instances where, because of recording interval, image quality, and audio recording settings, there is insufficient recording space on the uint’s hard disk drive to complete the Timer recording as programmed.

Please note that when the recording interval setting differs on the RECORDING SET UP screen and TIMER PROGRAM screen, the possible recording duration will differ from the duration displayed in ESTD TIME on the RECORDING SETTING screen.

When setting the Timer for multiple programs, please refer to the Recording time table on page 71 to confirm the amount of hard disk space the recording duration will take up under different setting conditions.

<TIMER PROGRAM>

P2￿

DW

START

END

MODE￿

1 DAY

12:00

15:00 AÐ 25F￿

@DAY 13:00 22:00 AÐ12.5F￿

3 ÐÐÐ ÐÐ:ÐÐ ÐÐ:ÐÐ ÐÐÐÐÐÐÐ￿

Using the Timer setting of as an example of estimating possible recording duration, the chart below shows that everything is recorded on the first day, and on the second day only remain 16.7% of Program 1 content is recorded on the hard disk drive. (Conditions ; recording picture grade is set to “HIGH”, Audio Recording is set to “OFF”, built-in 30GB hard disk drive, Storage Limit set to “OFF”.)

Program

Recording time

Possible duration for

HDD recording

for one day (A)

Consecutive Recording (B)

space (A/B)

 

 

 

 

 

1

3 hour ( 180 minutes)

9 hour (540 minutes)

33.3%

 

 

 

 

2

9 hour ( 540 minutes)

18 hour (1080 minutes)

50.0%

 

 

 

 

Setting SPECIAL DW (special day of the week) By entering a program’s start-day and end-day, the unit can be set to record during a specific time frame over any number of days in the week. The unit will record on the days entered into the program which displays “SPL” in its DW column.

Example: MON - FRI are designated as the days used in SETTING P1.

The settings for the start-day and the end-day cannot be identical.

1.Press the SET UP button to display the <MENU SETTING> menu.Turn the JOG dial to move the cursor to TIMER PROGRAM then turn the SHUTTLE ring to the right.

The <TIMER PROGRAM> menu will appear.

2.Turn the JOG dial to move the cursor to SETTING P1 then turn the SHUTTLE ring to the right to display the <TIMER PROGRAM> menu of P1.

<TIMER PROGRAM>￿

P1

SELECTED

PATTERN￿

@SETTING

P1￿

 

SETTING

P2￿

 

SETTING

P3

 

3.Turn the JOG dial to move the cursor to select “SPECIAL DW”, then turn the SHUTTLE ring to the right.

7 SPL 12:00 13:00 A- 25F￿

8 DAY 13:00 14:25 B-12.5F￿

@SPECIAL DW:TUEÐFRI

4.Turn the JOG dial to select “MON” then turn the SHUTTLE ring to the right.

7 SPL 12:00 13:00 A- 25F￿

8 DAY 13:00 14:25 B-12.5F￿

@SPECIAL DW:MONÐFRI

5.Turn the JOG dial to select “FRI” then turn the SHUTTLE ring to the right.

The flashing will stop.

7 SPL 12:00 13:00 A- 25F￿

8 DAY 13:00 14:25 B-12.5F￿

@SPECIAL DW:MONÐFRI

6.Press the TIMER REC button.

The TIMER REC indicator will illuminate.

If the current time is covered by a program, the unit will begin recording immediately.

If the current time is not covered by a program, the unit will turn the power off and go into stand-by mode.

Operation can be shut down completely by pressing the TIMER REC button once more.

The unit will not record if there is an error in Timer settings. The following provides a list of measures for dealing with errors in Timer settings.

Symptom 1)

The TIMER REC indicator is flashing. The buzzer sounds if the BUZZER setting is set to WRNG.

Content of this Error

1)The present time or the Timer is not set.

2)The timer program has been made on <TIMER PRO- GRAM> page, but the correct SELECTED PATTERN is not selected on the <TIMER PROGRAM> menu.

3)Menu setting is not yet completed.

Countermeasure

1)Set the correct present time (page 11).

2)Select the correct SELECTED PATTERN (page 43).

3)Complete the menu setting.

Symptom 2)

The Timer recording would not start even when the time is ready for timer recording.

•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••

••••••••••••

44