O p t i o n 5 0 ( B a r C o d e D e n s i t y )

You can apply this option to bar code fields when you want to create custom densities. When you apply this option, it overrides the density value in the bar code field. When using this option, set the density parameter in your bar code field to the default value. You can only use this option once for each bar code field. This option overrides the density selected in the bar code field.

Bar codes produced using Option 50 may not be scannable. Code 39, density 12, produces a one-dot narrow bar. This density is intended for special U.S.P.S. ACT-tag applications only. Synthetic supplies are recommended to produce scannable bar codes.

The additional character gap, narrow space, and wide space parameters are valid only with Code 39 and Codabar. If these parameters are specified for any other bar codes, they will be ignored by the printer. Do not use Option 50 with fixed density bar codes.

Syntax

R,50,narrow,wide,gap,nar_space,

 

wide_space p

R1. R

Option Header.

R2. 50

Option 50.

R3. narrow

Dot width of the narrow element. Range: 1-99.

R4. wide

Dot width of the wide element. Range: 1-99.

R5. gap

Additional dot space between characters. Enter a value of 1

 

to 99. (Code 39 and Codabar only.)

R6. nar_space

Additional dot width of the narrow bar code space. (Code 39

 

and Codabar only). Range: 1- 99.

R7. wide_space

Additional dot width of the wide bar code space. (Code 39

 

and Codabar only). Range: 1- 99.

Example

R,50,4,8,4,4,8 p

4-12Defining Field Options