Status2
B- Field Type
represents the MPCLII field that the error
occurred on. If the packet has no fields,
Status2 A will be replicated. If the error
occurs before the field is identified a question
mark is sent. Since the batch data is
variable, a D is sent to indicate data.
Status2
C- Field Number
represents the field number within each
packet. The packet header is the first field
and each subsequent field is indicated by the
field separator.
Status2
D- Parameter
represents the parameter within the field that
the error occurred. The numbering begins
after the field identifier.
Status2
E- Error Number
is the error that coincides with the error
numbers presented in Chapter 8, "Diagnostics
and Errors."
"FMT-1/BCH-2" The format or batch number is returned.
If more than one error occurred then only the
most serious error will be acknowledged.
{J,"","F,B,4,6,33","FMT-1","BCH-2"}
Indicates that an error occurred on a bar code (B) field within a
format (F) packet. The bar code field is the fourth (4) field in the
packet. The error occurred in the sixth (6) parameter of the field.
Error number 33 means the bar code density is invalid.
To clear an error, press ENTER or ESCAPE/CLEAR, depending
on your printer. An ENQ can also clear errors numbered less than
500. Once the error is corrected, a job request can be sent. The
printer cannot accept another job request until the error is
resolved.
Status Polling 7-11