The internal symbol set is used.

D e f i n i n g B a r C o d e F i e l d s

Each bar code field requires a separate definition.

Syntax

B,field#,# of char,fix/var,row,column,

 

font,density,height,text,alignment,

 

field rot p

 

 

B1. B

Bar Code Field.

 

 

B2. field#

Unique number from 0-999(0-99for 9403) to identify this field.

B3. # of char

Maximum number of characters. If the bar code uses a check

 

digit, allow an extra character for the check digit. The actual

 

maximum number of characters is limited by the size of the

 

label and bar code density. Range: 0-2710(0-100for 9403).

 

Data Matrix can use up to 2710 numeric characters or 2335

 

alphanumeric characters. Quick Response (QR Code) can

 

use 299-2710 characters. See Appendix A, "Samples" for

 

more information.

 

 

B4. fix/var

Fixed (F) or variable (V) length field.

 

 

 

 

 

Bar Code

 

Number of Characters

Fixed or

 

 

 

 

Variable

 

 

 

 

 

UPCA

 

 

12

F

 

 

 

 

 

UPCA+2

 

 

14

F

 

 

 

 

 

UPCA+5

 

 

17

F

 

 

 

 

 

UPCA+Price CD

 

 

12

F

 

 

 

 

 

UPCE

 

 

7

F

 

 

 

 

 

UPCE+2

 

 

9

F

 

 

 

 

 

UPCE+5

 

 

12

F

 

 

 

 

 

EAN8

 

 

8

F

 

 

 

 

 

EAN8+2

 

 

10

F

 

 

 

 

 

EAN8+5

 

 

13

F

 

 

 

 

 

EAN13

 

 

13

F

 

 

 

 

 

EAN13+2

 

 

15

F

 

 

 

 

 

EAN13+5

 

 

18

F

 

 

 

 

 

EAN13+Price CD

 

 

13

F

 

 

 

 

 

POSTNET

 

 

9 or 11

F

 

 

 

 

 

3-8Defining Fields

Page 66