Error Description

Code

001 Packet ID number must be 1 to 999.

002Name must be 1 to 8 characters inside quotes or a printer-assigned name ("").

003 Action must be A (add) or C (clear).

004Supply length is invalid. See "Defining the Format Header" in Chapter 3 for valid lengths.

005Supply width is invalid. See "Defining the Format Header" in Chapter 3 for valid widths.

006Storage device must be F (Flash), R (volatile RAM), or T (temporary for graphics).

007Unit of measure must be E (English), M (Metric), or G (Dots). See "Defining the Format Header" in Chapter 3 for information.

010Field ID number is outside the range 0 to 999 or 0 to 99 depending on your printer.

011Field length exceeds 2710 or 100 depending on your printer.

012Row field position is greater than the maximum stock dimension. See "Defining Text Fields" in Chapter 3 for valid row lengths.

013Column field position is greater than the maximum stock dimension. See "Defining Text Fields" in Chapter 3 for valid column widths.

014Font style must be 1, 2, 3, 4, 10, 11, 15, 16, 17, 18, or 50. See "Defining Text Fields" in Chapter 3 or Appendix B, "Fonts," for more information.

Diagnostics and Errors 8-7

Page 167
Image 167
Monarch 9403, 9850, 9825 manual Error Description Code