286The buffer size is invalid.

287The printhead width must be 0.

288The battery voltage must be 0 (15-volt battery) or 1 (12-volt battery).

289The printer address specified in the communication settings packet must use exactly six characters.

290Action must be 0 (disable) or 1 (enable) for the backfeed control packet or the printer is active.

291Dispense position must be 50 to 200 dots and the backfeed distance is greater than the dispense position or the printer is active.

292Backfeed distance must be 10 to 200 dots or the printer is active.

310Check digit scheme number must be 1 to 10.

311Modulus must be 2 to 11.

314Check digit algorithm must be D (sum of digits) or P (sum of products).

325Duplicating direction must be 0 (insert after) or 1 (insert before) in duplicate fields for graphics.

327Amount of row adjustment must be 0 to 999 (0 to 99 depending on your printer) dots in duplicate fields for graphics.

328Duplicate count must be 0 to 999 (0 to 99 depending on your printer).

340Bitmap line encoding must be H (hex) or R (run length).

350Font selector must be 1 to 9999.

351Font data length must be 68 to 16384.