Moxa Technologies NE-4100 Series User’s Manual, Web Console Configuration, Local time

Models: NE-4100

1 90
Download 90 pages 17.34 Kb
Page 39
Image 39
NE-4100 Series User’s Manual

NE-4100 Series User’s Manual

Web Console Configuration

 

Local time

 

 

 

 

Setting

Factory Default

Necessity

 

 

User adjustable time.

GMT (Greenwich Mean Time)

Optional

 

Click on the Modify button to open the Modify time settings window to input the correct local time.

Time server

Setting

Factory Default

Necessity

IP or Domain address

None

Optional

(E.g., 192.168.1.1, time.stdtime.gov.tw, or

 

 

time.nist.gov)

 

 

NE-4100 Series uses SNTP (RFC-1769) for auto time calibration.

Input the correct “Time Server” IP address or domain address. Once NE-4100 Series is configured with the correct Time Server address, NE-4100 Series will request time information from the “Time Server” every 10 minutes.

Console

The “Disable” option for Web Console and Telnet Console is included for security reasons. In some cases, you may want to Disable one or both of these Console utilities as an extra precaution to prevent unauthorized users from accessing your NE-4100 Series. The factory default for both Web Console and Telnet Console is Enable.

Setting

Factory Default

Necessity

Enable or Disable

Enable

Required

If you disable both the “Web Console” and “Telnet Console,” you can still use the Serial Console to configure NE-4100 Series locally, or Windows Administrator to configure NE-4100 Series either locally or remotely over the network.

6-4

Page 39
Image 39
Moxa Technologies NE-4100 Series User’s Manual, Web Console Configuration, Local time, Setting, Factory Default