NE-4100 Series User’s Manual

Web Console Configuration

The “Destination IP address” parameter can use both IP address and Domain address. For some applications, the user may need to send the data actively to the remote destination domain address.

TCP connection on

Setting

Factory Default

Necessity

Start up,

Start up

Optional

Any Character

 

 

 

 

 

Start up: Attempts to establish a TCP connection as soon as the NE-4100 Series is powered on.

Any Character: Attempts to establish a TCP connection as soon as the NE-4100 Series starts receiving serial data.

UDP Mode

Delimiter 1

Setting

Factory Default

Necessity

00 to FF

“0” for None

Optional

 

 

 

Delimiter 2

 

 

Setting

Factory Default

Necessity

00 to FF

“0” for None

Optional

 

 

 

Once the NE-4100 receives both delimiters through the serial port, it immediately packs all data currently in its buffer and sends it to the NE-4100’s Ethernet port.

Note: Delimiter 2 is optional. If left blank, then Delimiter 1 alone trips clearing of the buffer.

Delimiter 2 is optional. If left blank, then Delimiter 1 alone trips clearing of the buffer. If the size of the serial data received is greater than 1K, the NE-4100 will automatically pack the data and send it to the Ethernet. However, to use the delimiter function, you must at least enable Delimiter 1. If Delimiter 1 is left blank and Delimiter 2 is enabled, the delimiter function will not work properly.

6-15

Page 50
Image 50
Moxa Technologies NE-4100 user manual UDP Mode, TCP connection on