| Web Console Configuration | |||
| Flow control |
|
|
|
|
| Setting | Factory Default |
| Necessity |
|
| None, RTS/CTS, DTR/DSR, XON/XOFF | RTS/CTS |
| Required |
|
| FIFO |
|
|
|
|
| Setting | Factory Default |
| Necessity |
|
| Enable, Disable | Enable |
| Required |
|
|
|
|
|
|
|
Operating Settings
Click on the Operating Settings link on the left side of the screen to display operating settings. Make necessary changes to the settings and then click on Submit to validate the modifications.
TCP Server Mode
TCP alive check time
Setting | Factory Default | Necessity |
0 to 99 min | 7 min | Optional |
|
|
|
0 min: TCP connection is not closed due to an idle TCP connection.
1 to 99 min:
Inactivity time
Setting | Factory Default | Necessity |
0 to 65535 ms | 0 ms | Optional |
|
|
|
0 ms: TCP connection is not closed due to an idle serial line.
This parameter defines the maintenance status as Closed or Listen on the TCP connection. The connection is closed if there is no incoming or outgoing data through the serial port during the specific Inactivity time.
If the value of inactivity time is set to 0, the current TCP connection is maintained until there is a connection close request. Although inactivity time is disabled, the