PT-7728 User’s Manual Featured Functions
3-6
Speed
Setting Description Factory Default
Auto This allows the port to use the IEEE 802.3u
protocol to negotiate with connected devices. The
port and connected devices will determine the
best speed for that connection.
100M-Full
100M-Half
10M-Full
10M-Half
Choose one of these fixed speed options if the
connected Ethernet device has trouble
auto-negotiating for line speed.
Auto
FDX Flow Ctrl
This setting enables or disables flow control for the port when the port's Speed is set to Auto. The
final result will be determined by the Auto process between the PT-7728 and connected devices.
Setting Description Factory Default
Enable This enables flow control for this port when the
port's Speed is set to Auto.
Disable This disables flow control for this port when the
port's Speed is set to Auto.
Disable
MDI/MDIX
Setting Description Factory Default
Auto This allows the port to auto-detect the port type of
the connected Ethernet device and change the
port type accordingly.
MDI
MDIX
Choose MDI or MDIX if the connected Ethernet
device has trouble auto-negotiating for port type.
Auto
Network
Network settings allow users to modify the usual TCP/IP network parameters.