Moxa Technologies PT-7728 user manual Now Active, Master/Slave, Redundancy Protocol, Set as Master

Models: PT-7728

1 87
Download 87 pages 13.62 Kb
Page 37
Image 37

 

PT-7728 User’s Manual

 

Featured Functions

 

 

"Current Status" Items

 

 

 

 

Now Active

 

 

 

 

 

This shows which communication protocol is in use: Turbo Ring, Turbo Ring V2, RSTP, or

 

 

none.

 

 

 

 

 

Master/Slave

 

 

 

 

 

This indicates whether or not the PT-7728 is the master of the Turbo Ring. This field appears only

 

 

for Turbo Ring or Turbo Ring V2.

 

 

 

 

 

 

 

 

 

 

NOTE

The user does not need to assign the master to use Turbo Ring or Turbo Ring V2. If no master is

 

 

assigned, the Turbo Ring protocol will automatically assign master status to one of the PT series

 

 

Ethernet switches in the ring. The master is only used to determine which segment serves as the

 

 

backup path.

 

 

 

 

 

 

 

 

 

 

 

 

Redundant Ports Status (1st Port, 2nd Port)

 

 

 

 

Ring Coupling Ports Status (Coupling Port, Coupling Control Port)

 

 

The Ports Status indicators show Forwarding for normal transmission, Blocking if the port is

 

 

part of a backup path that is currently blocked, and Link down if there is no connection.

 

 

"Settings" Items

 

 

 

 

 

Redundancy Protocol

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting

Description

Factory Default

 

 

 

 

Turbo Ring

This selects the Turbo Ring

 

 

 

 

 

protocol.

 

 

 

 

 

 

 

 

 

 

 

Turbo Ring V2

This selects the Turbo Ring V2

 

 

 

 

 

protocol.

None

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RSTP (IEEE

This selects the RSTP protocol.

 

 

 

 

 

802.1W/1D)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

None

This disables ring redundancy.

 

 

 

 

 

 

 

 

 

 

 

Set as Master

 

 

 

 

 

 

Setting

Description

Factory Default

 

 

 

 

Enabled

The PT-7728 is manually selected

 

 

 

 

 

as the master.

 

 

 

 

 

 

Not checked

 

 

 

 

Disabled

The Turbo Ring or Turbo Ring V2

 

 

 

 

protocol will automatically select

 

 

 

 

 

 

the master.

 

 

 

 

Redundant Ports

 

 

 

 

 

 

 

 

 

 

 

 

Setting

Description

Factory Default

 

 

 

 

 

This specifies which port on the

 

 

 

 

 

1st Port

PT-7728 will be used as the first

None

 

 

 

 

 

redundant port.

 

 

 

 

 

 

This specifies which port on the

 

 

 

 

 

2nd Port

PT-7728 will be used as the second

None

 

 

 

 

 

redundant port.

 

 

3-23