Moxa Technologies PT-7728 user manual 802.1X Re-Authentication, Local User Database Setup

Models: PT-7728

1 87
Download 87 pages 13.62 Kb
Page 68
Image 68

PT-7728 User’s Manual

 

Featured Functions

 

Re-Auth

 

 

 

 

 

 

 

 

 

 

 

Setting

Description

 

Factory Default

 

 

Enable/Disable

Select to require re-authentication of the client after a

 

Disable

 

 

 

preset time period of no activity has elapsed.

 

 

 

 

Re-Auth Period

 

 

 

 

 

Setting

Description

 

Factory Default

 

 

Numerical

Specify how frequently the end stations need to reenter

 

3600

 

 

(60 to 65535 sec.)

usernames and passwords in order to stay connected.

 

 

 

 

802.1X

 

 

 

 

 

 

 

 

 

 

Setting

Description

 

Factory Default

 

 

Enable/Disable

Click the checkbox under the 802.1X column to enable

 

Disable

 

 

 

IEEE 802.1X for one or more ports. All end stations

 

 

 

 

 

must enter usernames and passwords before access to

 

 

 

 

 

these ports is allowed.

 

 

 

802.1X Re-Authentication

The PT-7728 can force connected devices to be re-authorized manually.

802.1X Re-Authentication

Setting

Description

Factory Default

Enable/Disable

This enables or disables 802.1X Re-Authentication

Disable

Local User Database Setup

When setting the Local User Database as the authentication database, set the database first.

3-54

Page 68
Image 68
Moxa Technologies PT-7728 user manual 802.1X Re-Authentication, Local User Database Setup