ION 7500 / ION 7600 User’s Guide

Customizing the Vista Interface

 

 

Analog Inputs/Outputs

The optional Analog I/O card must be installed on your meter for this diagram to function. Depending on which option you chose for your card, the Analog I/O diagram monitors either analog inputs or analog outputs, or it monitors both the inputs and outputs.

Inputs

The meter’s analog inputs are monitored for the ScaledValu output register. This value is displayed next to the appropriate port.

Outputs

The meter’s analog outputs are monitored for the Normalized output register. This value is displayed next to its port.

Refer to the technical note Digital and Analog I/O for more information on analog inputs and outputs and their associated output registers.

Revenue Test Mode

The Revenue Test Mode diagram shows TEST mode parameters. The energy and demand values displayed only accumulate when the meter is in TEST mode. See “Setup and Controls” on page 98 for instructions on placing the meter in TEST mode.

Revenue Test Mode Values

Accumulated values of active, reactive, and apparent energy (delivered, received, and delivered + received)

Sliding window and thermal demand for active power (delivered, received, delivered peak, and received peak)

All TEST mode values are cleared once you exit TEST mode

A red, flashing TEST mode label appears above the Energy label when the meter is in Revenue TEST mode.

Customizing the Vista Interface

Standard Vista diagrams show much of the data that the factory-configured meter measures and calculates. However, the factory-configured meter can provide additional data that is not presented by default with these display tools. This data can be added to the standard Vista diagrams by placing addition diagram objects on them; or, you can create new user diagrams to display any additional data you want.

Vista cannot be used to customize data displays on the ION meters themselves.

NOTE

Level 5 ION software authority (Supervisor) is required to create and configure new Vista diagrams. If you do not have Level 5 password authority, contact your ION software administrator for assistance.

Chapter 4 - Using ION Software

Page 101

Page 101
Image 101
Multi-Tech Systems 7500, 7600 manual Customizing the Vista Interface, Analog Inputs/Outputs, Revenue Test Mode

7500, 7600 specifications

Multi-Tech Systems has established a strong reputation in the realm of communication technology, particularly known for its innovative products that cater to various industrial applications. Among their popular offerings are the Multi-Tech Systems 7600 and 7500 series, both designed to address the increasing demand for reliable, efficient, and flexible communication solutions in a connected world.

The Multi-Tech 7600 series is renowned for its robust design and multifunctional capabilities. One of its main features is support for multiple communication protocols, including cellular, wired, and wireless networks, ensuring seamless connectivity across different platforms. This versatility makes it an ideal choice for applications in industries such as transportation, healthcare, and logistics. The device is equipped with advanced signal processing technology, which enables it to maintain high-quality connections even in challenging environments.

On the other hand, the Multi-Tech 7500 series focuses more on the integration of IoT (Internet of Things) technologies. This series is particularly adept at connecting various smart devices, allowing for real-time data transmission and monitoring. Key features include extensive support for low-power wide-area network standards, making it an excellent option for applications that require long-range connectivity while minimizing power consumption. This characteristic is particularly advantageous for battery-operated devices deployed in remote locations.

Both series are built on versatile hardware platforms that allow for scalability and customization, catering to the unique needs of different industries. With embedded security features, including encryption and secure protocols, they provide a high level of protection for sensitive data, making them suitable for sectors that prioritize security, such as financial services and healthcare.

In terms of characteristics, both the 7600 and 7500 series are designed for ease of integration, featuring user-friendly interfaces and comprehensive development tools. This empowers developers to quickly deploy solutions and minimizes time to market. Additionally, the products offer extensive documentation and support, facilitating efficient onboarding for new users.

Overall, Multi-Tech Systems’ 7600 and 7500 series provide a powerful combination of features, technologies, and characteristics that make them standout choices for organizations looking to enhance their communication capabilities in a rapidly evolving digital landscape. Their capability to connect and interact with a wide range of devices and protocols ensures that businesses can adapt, innovate, and thrive in an increasingly connected world.