Multi-Tech Systems 7500, 7600 Multi-Tech Modems in ION Meters, Multi-Tech Internal Modem Settings

Models: 7500 7600

1 372
Download 372 pages 61.31 Kb
Page 283
Image 283

ION 7500 / ION 7600 User’s GuideMulti-Tech Modems in ION Meters

Multi-Tech Modems in ION Meters

The Multi-Tech ModemModuleTM is the newer-type modem equipped in ION meters that are ordered with the internal modem option. The Multi-Tech modem is compatible with most telephone systems in the world, with the exception of Australia and New Zealand.

Multi-Tech Internal Modem Settings

Since the Multi-Tech modem are universally compatible with most telephone systems, no further reconfiguration of the default settings should be necessary.

International support

In some cases, the default initialization string for the internal (Multi-Tech) modem may need to be changed depending on the country it is used in. Countries not listed below are compatible with the default (North American) settings:

Hong Kong, Hungary, India, Indonesia, Israel, Korea, Malaysia, Philippines,

Poland, Singapore, Slovenia and Vietnam

AT%T19,0,30

Czech Republic

AT%T19,0,25

Japan

AT%T19,0,10

AT Commands for the Multi-Tech Modem

The following table summarizes the compatible AT commands for ION meters equipped with the Multi-Tech internal modems:

Command

 

Values

Default

Description

 

 

 

 

 

AT

Attention Code

n/a

 

The attention code precedes all command lines except

 

 

A/, A:, and escape sequences.

 

 

 

 

 

 

 

 

 

A/

Repeat Last Command

n/a

 

Repeat the last command string. Do not precede this

 

command with AT. Do not press ENTER to execute.

 

 

 

 

 

 

 

 

 

 

 

 

 

B0 Select ITU-T V.22 mode when modem is at 1200

 

 

 

 

bps.

 

Communication

 

 

B1 Select Bell 212A when modem is at 1200 bps.

Bn

n = 0–3, 15, 16

1 and 16

B2 Deselect V.23 reverse channel (same as B3).

Standard Setting

 

 

 

B3 Deselect V.23 reverse channel (same as B2).

 

 

 

 

 

 

 

 

B15 Select V.21 when the modem is at 300 bps.

 

 

 

 

B16 Select Bell 103J when the modem is at 300 bps.

 

 

 

 

 

 

 

 

 

N0 Modem performs handshake only at

 

 

 

 

communication standard specified by S37 and the B

Nn

Modulation Handshake

n = 0 or 1

1

command.

N1 Modem begins handshake at communication

 

 

 

 

 

 

 

 

standard specified by S37 and the B command. During

 

 

 

 

handshake, fallback to a lower speed can occur.

 

 

 

 

 

Modem AT Commands Technical Note

Page 283

Page 283
Image 283
Multi-Tech Systems 7500, 7600 Multi-Tech Modems in ION Meters, Multi-Tech Internal Modem Settings, International support

7500, 7600 specifications

Multi-Tech Systems has established a strong reputation in the realm of communication technology, particularly known for its innovative products that cater to various industrial applications. Among their popular offerings are the Multi-Tech Systems 7600 and 7500 series, both designed to address the increasing demand for reliable, efficient, and flexible communication solutions in a connected world.

The Multi-Tech 7600 series is renowned for its robust design and multifunctional capabilities. One of its main features is support for multiple communication protocols, including cellular, wired, and wireless networks, ensuring seamless connectivity across different platforms. This versatility makes it an ideal choice for applications in industries such as transportation, healthcare, and logistics. The device is equipped with advanced signal processing technology, which enables it to maintain high-quality connections even in challenging environments.

On the other hand, the Multi-Tech 7500 series focuses more on the integration of IoT (Internet of Things) technologies. This series is particularly adept at connecting various smart devices, allowing for real-time data transmission and monitoring. Key features include extensive support for low-power wide-area network standards, making it an excellent option for applications that require long-range connectivity while minimizing power consumption. This characteristic is particularly advantageous for battery-operated devices deployed in remote locations.

Both series are built on versatile hardware platforms that allow for scalability and customization, catering to the unique needs of different industries. With embedded security features, including encryption and secure protocols, they provide a high level of protection for sensitive data, making them suitable for sectors that prioritize security, such as financial services and healthcare.

In terms of characteristics, both the 7600 and 7500 series are designed for ease of integration, featuring user-friendly interfaces and comprehensive development tools. This empowers developers to quickly deploy solutions and minimizes time to market. Additionally, the products offer extensive documentation and support, facilitating efficient onboarding for new users.

Overall, Multi-Tech Systems’ 7600 and 7500 series provide a powerful combination of features, technologies, and characteristics that make them standout choices for organizations looking to enhance their communication capabilities in a rapidly evolving digital landscape. Their capability to connect and interact with a wide range of devices and protocols ensures that businesses can adapt, innovate, and thrive in an increasingly connected world.