Current Probe Inputs Basic Setup

Meters with the Current Probes Input Option are compatible with clamp-on current probes. All current inputs on these meters are modified to accept 0-5 Vrms AC signals from a variety of clamp-on current probes. This option reduces the downtime required to install a meter. There are two Current Probe Input Option configurations:

A.Meters calibrated and shipped with probes: the meter is pre-configured and calibrated at the factory with three Universal Technic 10A current probes, meeting IEC 1036 Class 1 accuracy levels which includes the meter and the current probes accuracy. The current probes can be used for monitoring 1A or 5A secondaries. Probe cable is 22 AWG (0.3 mm2) and two meters in length.

B.Meters calibrated, but not with probes: this option allows you to order a meter that is calibrated for use with current probes. You then supply your own probes (as long as they match the input specifications of the meter) or select one of the several compatible models available from PML as accessories. Probes and probe cables must be compliant with IEC 61010-1 CATIII protection requirements and not require more than 220k Ohm of load impedance.

Whether basic setup is necessary depends on your Current Probe Input Option.

Basic Setup is NOT required:

If your ordering option includes PML supplied current probes and a meter factory- calibrated to match the current probe specifications (option “A” above).

If you have this ordering option, then this document does not apply to you.

Basic Setup IS required:

If your meter ordering option does not include current probes that have been factory-calibrated with the meter (option “B” above). In this case, you need to set up the transformation ratio for the current probes you will be using. If energy readings accuracy is important, then you need to set up the phase angle specified by the current probe manufacturer. To learn how to do this setup, read the following instructions.

In This Document

Telnet and HyperTerminal Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186 Current Probe Basic Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186

To perform current probe basic setup: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187

Calibration Menu and the KCTSTP/KCTRD Commands . . . . . . . . . . . . . . . 188

Calibration Menu and Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188 Description of KCTSTP and KCTRD Calibration Commands . . . . . . . . . . . . . . 188

Page 185
Image 185
Multi-Tech Systems 7500, 7600 Basic Setup is not required, Basic Setup is required, To perform current probe basic setup

7500, 7600 specifications

Multi-Tech Systems has established a strong reputation in the realm of communication technology, particularly known for its innovative products that cater to various industrial applications. Among their popular offerings are the Multi-Tech Systems 7600 and 7500 series, both designed to address the increasing demand for reliable, efficient, and flexible communication solutions in a connected world.

The Multi-Tech 7600 series is renowned for its robust design and multifunctional capabilities. One of its main features is support for multiple communication protocols, including cellular, wired, and wireless networks, ensuring seamless connectivity across different platforms. This versatility makes it an ideal choice for applications in industries such as transportation, healthcare, and logistics. The device is equipped with advanced signal processing technology, which enables it to maintain high-quality connections even in challenging environments.

On the other hand, the Multi-Tech 7500 series focuses more on the integration of IoT (Internet of Things) technologies. This series is particularly adept at connecting various smart devices, allowing for real-time data transmission and monitoring. Key features include extensive support for low-power wide-area network standards, making it an excellent option for applications that require long-range connectivity while minimizing power consumption. This characteristic is particularly advantageous for battery-operated devices deployed in remote locations.

Both series are built on versatile hardware platforms that allow for scalability and customization, catering to the unique needs of different industries. With embedded security features, including encryption and secure protocols, they provide a high level of protection for sensitive data, making them suitable for sectors that prioritize security, such as financial services and healthcare.

In terms of characteristics, both the 7600 and 7500 series are designed for ease of integration, featuring user-friendly interfaces and comprehensive development tools. This empowers developers to quickly deploy solutions and minimizes time to market. Additionally, the products offer extensive documentation and support, facilitating efficient onboarding for new users.

Overall, Multi-Tech Systems’ 7600 and 7500 series provide a powerful combination of features, technologies, and characteristics that make them standout choices for organizations looking to enhance their communication capabilities in a rapidly evolving digital landscape. Their capability to connect and interact with a wide range of devices and protocols ensures that businesses can adapt, innovate, and thrive in an increasingly connected world.