ION 7500 / ION 7600 User’s Guide

Configuring Communications

 

 

Configuring Communications

Before you can talk to the devices on your network, you need to configure communications within the ION Management Console. Essentially, this means adding one or more sites and then adding the devices associated with each site. If you create a modem site, then you also need to add and configure a dialout modem. There may be instances where you want to add a new server (either another computer or third-party gateway); the computer running the ION Enterprise software is considered a server and is listed in the Server section.

Adding a new Server, Site, Device or Dialout Modem:

1.Click the appropriate network component icon (Servers, Sites, Devices, Dialout Modems) in the System Setup pane. The title bar reflects your selection.

2.Right-click in the display window, select New and the type of Server, Site, Device. If you are configuring a modem you only have one New option.

3.Configure the item using the drop-down list boxes and manually entering values where required.

4.Right click in the Properties dialog box to access Advanced Properties. You can use the drop-down list boxes or manually enter new values as required.

5.Click OK when you are done.

The process of adding network components to the ION Management Console is the same for each component — the difference lies in how you configure the components. When the Properties dialog appears for the component you added, the fields for which you are required to provide information are highlighted in red. For example, the illustration below shows the required fields when adding a new Ethernet device:

Although Group has a drop down list box, you are not restricted to the values in the list. If you want to create a new group, simply type its name in the value field. Other drop down list boxes restrict you to the values in the list.

The Properties dialog has different required fields depending on which component you are adding:

For a Direct Site you specify the serial port (COM1, COM 2, etc.) on the server computer where the serial device (or network of serial devices) is connected. You must specify the server computer that communicates with the direct site.

For a Modem Site you provide information about the modem at the (remote) modem site: baud rate, modem telephone number, etc. You also specify the server computer that communicates with the modem site.

Chapter 4 - Using ION Software

Page 91

Page 91
Image 91
Multi-Tech Systems 7500, 7600 manual Configuring Communications, Adding a new Server, Site, Device or Dialout Modem

7500, 7600 specifications

Multi-Tech Systems has established a strong reputation in the realm of communication technology, particularly known for its innovative products that cater to various industrial applications. Among their popular offerings are the Multi-Tech Systems 7600 and 7500 series, both designed to address the increasing demand for reliable, efficient, and flexible communication solutions in a connected world.

The Multi-Tech 7600 series is renowned for its robust design and multifunctional capabilities. One of its main features is support for multiple communication protocols, including cellular, wired, and wireless networks, ensuring seamless connectivity across different platforms. This versatility makes it an ideal choice for applications in industries such as transportation, healthcare, and logistics. The device is equipped with advanced signal processing technology, which enables it to maintain high-quality connections even in challenging environments.

On the other hand, the Multi-Tech 7500 series focuses more on the integration of IoT (Internet of Things) technologies. This series is particularly adept at connecting various smart devices, allowing for real-time data transmission and monitoring. Key features include extensive support for low-power wide-area network standards, making it an excellent option for applications that require long-range connectivity while minimizing power consumption. This characteristic is particularly advantageous for battery-operated devices deployed in remote locations.

Both series are built on versatile hardware platforms that allow for scalability and customization, catering to the unique needs of different industries. With embedded security features, including encryption and secure protocols, they provide a high level of protection for sensitive data, making them suitable for sectors that prioritize security, such as financial services and healthcare.

In terms of characteristics, both the 7600 and 7500 series are designed for ease of integration, featuring user-friendly interfaces and comprehensive development tools. This empowers developers to quickly deploy solutions and minimizes time to market. Additionally, the products offer extensive documentation and support, facilitating efficient onboarding for new users.

Overall, Multi-Tech Systems’ 7600 and 7500 series provide a powerful combination of features, technologies, and characteristics that make them standout choices for organizations looking to enhance their communication capabilities in a rapidly evolving digital landscape. Their capability to connect and interact with a wide range of devices and protocols ensures that businesses can adapt, innovate, and thrive in an increasingly connected world.