Multi-Tech Systems 7500, 7600 manual RS-485 Connections, Specifications are as follows

Models: 7500 7600

1 372
Download 372 pages 61.31 Kb
Page 165
Image 165

ION 7500 / ION 7600 User’s Guide

COM1 Port

 

 

RS-485

COM

SH + --

External Modem Connections

Specification

Description

 

 

Cable Type

Standard straight-through RS-232 cable

 

 

Cable Ends

DB9 female end for mating with the DB9 male connector on the meter

 

 

Max. Cable Length

50 feet (15.2 m)

 

 

RS-485 Connections

RS-485 connections are made via the captured-wire connectors on the rear of the meter. Devices can be connected in series using RS-485 (see diagram to the left). Be sure not to ground the wires at both ends.

Specifications are as follows:

Specification

Value

 

 

Baud Rates

300 to 57,600 bps (default is 9,600 bps)

 

 

Duplex

Half

 

 

Supported Protocols

ION, Modbus RTU, DNP 3.0, FACTORY, Iec870-102, GPS: Arbiter,

GPS: TRUE TIME DATUM, EtherGate, ModemGate (default is ION)

 

 

 

 

Optical isolation from all other inputs and outputs (the COM1 RS-485 port

Isolation

is not isolated from the COM1 RS-232 port); isolation voltage is 750 V

 

peak for 10 seconds @ 60 Hz.

 

 

Connections

Specification

Description

 

 

Cable Type

Good quality shielded twisted pair cable, AWG 22 or larger.

 

 

Max. Cable Length

4,000 ft. (1219 m) 1

Max. number of

32

devices per bus

 

 

 

1The lengths of all (+ and –) cable segments must be counted including those that connect devices to terminal blocks.

Terminal connections on the meter are marked as follows:

Marking

Terminal Function

 

 

 

SHLD

RS-485

Shield

 

 

 

RS-485

Data Minus

 

 

 

+

RS-485

Data Plus

 

 

 

Chapter 6 - Hardware Reference

Page 165

Page 165
Image 165