ION 7500 / ION 7600 User’s Guide

Pre-configured Reports

 

 

Energy and Demand

This report is designed to generate and display details about energy consumption and peak demand levels over a given time period. It uses a Time of Use Schedule (TOU) to reference the metered data against an energy provider’s tariff schedule.

The first step in creating an Energy and Demand report is to preconfigure the TOU schedule that will be applied to the metered data. If you do not require a time of use schedule, you can create a mock schedule with only one time period defined. Use the EgyDmd Log as a query item.

Load Profile

This report generates a graphical representation of demand, or load levels, over a given time frame. The profile is a characterization of peak loads that can be used to determine and limit demand peaks which could lead to financial penalties for energy consumers, or could signal a need for additional generation or the introduction of load control programs for energy suppliers.

The Load Profile report also uses the EgyDmd Log as a query item, but it does not use a TOU schedule.

Power Quality

This report summarizes the number and severity of sags, swells, and transients over a given time range, and graphically represents the waveform captures of each individual event for further analysis.

The Power Quality report is slightly different than the other two report types, mainly in its requirements for different data log sources. The Power Quality report requires a combination of the Sag/Swell Log, Transient Log, and Waveform Log.

NOTE

You generate a Power Quality report with a combination of the Sag/Swell logs, Transient logs, and Waveform logs from the ION meters that have these as features. For example, the ION 7350 uses a Sag/ Swell module and Waveform capture to generate a Power Quality report; however, the ION 7600 has the Sag/Swell Log, Transient Log, and Waveform Log, so all three sources are used for a Power Quality report.

EN50160

EN50160 is a general power quality standard used by energy suppliers and energy consumers in European countries. The report is a summary of the multiple pass/fail results of the evaluation methods outlined in the standard. All fourteen of the logs below must be added to each EN50160_General report:

EN50160 Vlt Dp1 to EN50160 Vlt Dp5

EN50160 Ovrvlt1 to EN50160 Ovrvlt3

EN50160 Frq/Mg, EN50160 Flicker, EN50160 Intrp, EN50160 Hrm Vlt, EN50160 Ihm Vlt, and EN50160 Vunbal

EN50160 MSignal is the log used for the EN50160_Mains_Signal report.

Chapter 4 - Using ION Software

Page 115

Page 115
Image 115
Multi-Tech Systems 7500, 7600 manual Energy and Demand, Load Profile, Power Quality, EN50160

7500, 7600 specifications

Multi-Tech Systems has established a strong reputation in the realm of communication technology, particularly known for its innovative products that cater to various industrial applications. Among their popular offerings are the Multi-Tech Systems 7600 and 7500 series, both designed to address the increasing demand for reliable, efficient, and flexible communication solutions in a connected world.

The Multi-Tech 7600 series is renowned for its robust design and multifunctional capabilities. One of its main features is support for multiple communication protocols, including cellular, wired, and wireless networks, ensuring seamless connectivity across different platforms. This versatility makes it an ideal choice for applications in industries such as transportation, healthcare, and logistics. The device is equipped with advanced signal processing technology, which enables it to maintain high-quality connections even in challenging environments.

On the other hand, the Multi-Tech 7500 series focuses more on the integration of IoT (Internet of Things) technologies. This series is particularly adept at connecting various smart devices, allowing for real-time data transmission and monitoring. Key features include extensive support for low-power wide-area network standards, making it an excellent option for applications that require long-range connectivity while minimizing power consumption. This characteristic is particularly advantageous for battery-operated devices deployed in remote locations.

Both series are built on versatile hardware platforms that allow for scalability and customization, catering to the unique needs of different industries. With embedded security features, including encryption and secure protocols, they provide a high level of protection for sensitive data, making them suitable for sectors that prioritize security, such as financial services and healthcare.

In terms of characteristics, both the 7600 and 7500 series are designed for ease of integration, featuring user-friendly interfaces and comprehensive development tools. This empowers developers to quickly deploy solutions and minimizes time to market. Additionally, the products offer extensive documentation and support, facilitating efficient onboarding for new users.

Overall, Multi-Tech Systems’ 7600 and 7500 series provide a powerful combination of features, technologies, and characteristics that make them standout choices for organizations looking to enhance their communication capabilities in a rapidly evolving digital landscape. Their capability to connect and interact with a wide range of devices and protocols ensures that businesses can adapt, innovate, and thrive in an increasingly connected world.