Multi-Tech Systems 7500 Display Setup, Display Options Module Settings, Scroll Module Settings

Models: 7500 7600

1 372
Download 372 pages 61.31 Kb
Page 63
Image 63

ION 7500 / ION 7600 User’s GuideDisplay Setup

Display Setup

The meter’s front panel display is controlled by three types of ION modules: the

Display Options module, the Scroll module, and Display modules.

Display Options Module Settings

The Display Options module contains setup registers that hold data display settings such as contrast level, backlight timeout, daylight savings time, and update time. Settings in the Display Options modules are global, and affect the entire set of front panel display screens.

Setup Register

Function

Default

 

 

 

Contrast

Sets the global contrast setting for the meter display.

7

 

 

 

Backlight Timeout

Sets the time that the front panel’s backlight stays on after the last press of a front

300

panel button (in seconds).

 

 

 

 

 

Display Update Time

Sets the period between data display refreshes (in seconds).

1

 

 

 

Digital Grouping

Sets the numbering format by determining how groups of three digits are

1,000

separated.

 

 

 

 

 

Demand Lockout Timeout

Sets the minimum time allowed between consecutive demand resets.

2,160,000

 

 

 

 

Scroll Module Settings

 

 

 

The Scroll module determines the sequence and rate of scrolling for multiple front

 

panel display screens.

 

 

 

 

 

 

Setup Register

Function

 

Default

 

 

 

 

Scroll Delay

Sets the time that will elapse between successive pulses on the Trigger outputs when the

6

scroll module is enabled.

 

 

 

 

 

 

 

 

Wraparound

Designates the last Trigger output (Trigger n) before returning to the first Trigger in

10

he order.

 

 

 

 

 

 

 

 

Freeze Time

Sets the time (in seconds) that the Scroll module remains "frozen" when pulsed from the

120

Freeze, Up, or Down inputs.

 

 

 

 

 

 

 

 

 

The Trigger outputs of Scroll module are linked to the inputs of Display modules.

 

When a pulse is sent from the Trigger output of a Scroll module to a linked Display

 

module, the Display module shows its information on the front panel.

 

Display Module Settings

 

 

 

Display modules determine the form and content of each display screen.

 

 

 

 

Setup Register

Function

Default

 

 

 

 

 

Screen Type

This specifies the way the linked parameters are displayed on the front panel

 

 

screen.

 

 

 

Defaults vary among display

 

 

 

 

Softkey Number

This assigns a softkey number to the display screen.

screens. Refer to the ION

 

 

Device Templates at

Softkey Name

This assigns a softkey name to the display screen.

www.pwrm.com.

 

 

 

 

Screen Title

This assigns a title to the display screen.

 

 

 

 

 

 

Chapter 3 - Default Meter Functionality

Page 63

Page 63
Image 63
Multi-Tech Systems 7500 Display Setup, Display Options Module Settings, Scroll Module Settings, Panel display screens

7500, 7600 specifications

Multi-Tech Systems has established a strong reputation in the realm of communication technology, particularly known for its innovative products that cater to various industrial applications. Among their popular offerings are the Multi-Tech Systems 7600 and 7500 series, both designed to address the increasing demand for reliable, efficient, and flexible communication solutions in a connected world.

The Multi-Tech 7600 series is renowned for its robust design and multifunctional capabilities. One of its main features is support for multiple communication protocols, including cellular, wired, and wireless networks, ensuring seamless connectivity across different platforms. This versatility makes it an ideal choice for applications in industries such as transportation, healthcare, and logistics. The device is equipped with advanced signal processing technology, which enables it to maintain high-quality connections even in challenging environments.

On the other hand, the Multi-Tech 7500 series focuses more on the integration of IoT (Internet of Things) technologies. This series is particularly adept at connecting various smart devices, allowing for real-time data transmission and monitoring. Key features include extensive support for low-power wide-area network standards, making it an excellent option for applications that require long-range connectivity while minimizing power consumption. This characteristic is particularly advantageous for battery-operated devices deployed in remote locations.

Both series are built on versatile hardware platforms that allow for scalability and customization, catering to the unique needs of different industries. With embedded security features, including encryption and secure protocols, they provide a high level of protection for sensitive data, making them suitable for sectors that prioritize security, such as financial services and healthcare.

In terms of characteristics, both the 7600 and 7500 series are designed for ease of integration, featuring user-friendly interfaces and comprehensive development tools. This empowers developers to quickly deploy solutions and minimizes time to market. Additionally, the products offer extensive documentation and support, facilitating efficient onboarding for new users.

Overall, Multi-Tech Systems’ 7600 and 7500 series provide a powerful combination of features, technologies, and characteristics that make them standout choices for organizations looking to enhance their communication capabilities in a rapidly evolving digital landscape. Their capability to connect and interact with a wide range of devices and protocols ensures that businesses can adapt, innovate, and thrive in an increasingly connected world.