Multi-Tech Systems 7600, 7500 manual Removing a Display Screen, Adding a New Display Screen

Models: 7500 7600

1 372
Download 372 pages 61.31 Kb
Page 198
Image 198

Removing a Display Screen

ION 7500 / ION 7600 User’s Guide

 

 

You can find instructions on reinitializing factory configurations in your User’s

Guide.

Removing a Display Screen

Use caution when deleting modules, as any dependant modules are also affected.

Designer informs you of dependant modules if they exist on the same node.

To remove a data display screen:

1.Launch Designer.

2.Select the Display module responsible for the screen.

3.Press delete. This also deletes all links to that particular Display module.

If the display screen you are deleting is part of the automatic scrolling cycle, you should reconfigure the links from the Scroll module’s Trigger outputs to the remaining Display modules so that the following considerations hold true:

The first Display module in the scrolling cycle is linked to the Trigger 1 output of the Scroll module.

The last Display module in the scrolling cycle (module n) is linked to the Trigger n output of the Scroll module. For example, if your scrolling cycle consists of 5 screens, then Trigger 5 should be linked to the fifth module in the cycle.

The Wraparound setup register of the Scroll module designates the last trigger output (Trigger n). Expanding on the previous example, since Trigger 5 is the last trigger, the Scroll module’s Wraparound setup register would have a value of 5.

Adding a New Display Screen

For the ION 8000 Series, ION 7500, and ION 7600 meters, you can create a new front panel display without dismantling any of the existing displays.

NOTE

You cannot add a new display screen for the ION 7300 Series meters; there are no available Display modules that you can create. Instead, you must re-configure one of the existing factory-configured display screens. See the following section “Changing Displayed Parameters in an Existing Screen” on page 199.

To add a new display screen in Designer:

1.Create a Display module.

2.Define the modules characteristics (display format) by adjusting its setup registers.

3.Link any required data to the Source inputs of the Display module.

If you want your new screen to appear in the automatic scrolling cycle, then you must link the Show input of the Display module to a Trigger output of a Scroll module. See “Removing a Display Screen” on page 198 for considerations on re- linking Scroll module Trigger outputs.

Page 198

Custom Front Panel Displays Technical Note

Page 198
Image 198
Multi-Tech Systems 7600, 7500 manual Removing a Display Screen, Adding a New Display Screen, To remove a data display screen

7500, 7600 specifications

Multi-Tech Systems has established a strong reputation in the realm of communication technology, particularly known for its innovative products that cater to various industrial applications. Among their popular offerings are the Multi-Tech Systems 7600 and 7500 series, both designed to address the increasing demand for reliable, efficient, and flexible communication solutions in a connected world.

The Multi-Tech 7600 series is renowned for its robust design and multifunctional capabilities. One of its main features is support for multiple communication protocols, including cellular, wired, and wireless networks, ensuring seamless connectivity across different platforms. This versatility makes it an ideal choice for applications in industries such as transportation, healthcare, and logistics. The device is equipped with advanced signal processing technology, which enables it to maintain high-quality connections even in challenging environments.

On the other hand, the Multi-Tech 7500 series focuses more on the integration of IoT (Internet of Things) technologies. This series is particularly adept at connecting various smart devices, allowing for real-time data transmission and monitoring. Key features include extensive support for low-power wide-area network standards, making it an excellent option for applications that require long-range connectivity while minimizing power consumption. This characteristic is particularly advantageous for battery-operated devices deployed in remote locations.

Both series are built on versatile hardware platforms that allow for scalability and customization, catering to the unique needs of different industries. With embedded security features, including encryption and secure protocols, they provide a high level of protection for sensitive data, making them suitable for sectors that prioritize security, such as financial services and healthcare.

In terms of characteristics, both the 7600 and 7500 series are designed for ease of integration, featuring user-friendly interfaces and comprehensive development tools. This empowers developers to quickly deploy solutions and minimizes time to market. Additionally, the products offer extensive documentation and support, facilitating efficient onboarding for new users.

Overall, Multi-Tech Systems’ 7600 and 7500 series provide a powerful combination of features, technologies, and characteristics that make them standout choices for organizations looking to enhance their communication capabilities in a rapidly evolving digital landscape. Their capability to connect and interact with a wide range of devices and protocols ensures that businesses can adapt, innovate, and thrive in an increasingly connected world.