Energy Pulsing from ION Meters

ION 7500 / ION 7600 User’s Guide

 

 

Energy Pulsing from ION Meters

If you wish to use one of the digital outputs on an ION 7300 Series, ION 7500, ION 7600, or ION 8000 meter for energy pulsing applications (Wh, kVAh, kVARh), assign it any Pulser, Digital Output, or Calibration Pulser module.

NOTE

In the ION 7300 Series, ION 7500, and ION 7600 meters,ION 7600, one of the solid-state relays (DO4) is preconfigured for calibration pulsing. It outputs a pulse for every 1.8 Wh measured and is controlled by the Calibration Pulser module. This default configuration can be disabled. Refer to the meter’s User’s Guide to learn how to disable this default configuration.

On all these meters, an energy pulsing LED is preconfigured to pulse every 1.8 Wh (1.2 Wh on 35S socket meters). A Calibration Pulser module controls it. You can configure the LED for other energy pulsing applications (kVAh, kVARh) by disabling the default configuration and then assigning it any Pulser, Digital Output, or Calibration Pulsar module.

On the ION 6200, two Pulser software modules are pre-set to send pulses every 1 kWh and every 1 kVARh to the solid state relays on the meter.

The infrared port on the ION 7300 Series meters can also be used for energy pulsing. To do this, you must set the communications protocol to INFRARED I/O. Then choose one of the Pulser modules and specify the infrared port in its setup register.

One Digital Output, Calibration Pulser, or Pulser ION module corresponds to each physical output port.

Digital Output module: A Digital Output module takes a Boolean input and sends it out a hardware channel as a constant level or a complete pulse.

Calibration Pulser module: All ION meters have Calibration Pulser modules that allow you to generate high accuracy energy pulses for calibration testing. They integrate instantaneous power inputs. A Calibration Pulser module takes numeric input and sends a pulse out a hardware channel based on the calibration constant (Kt). This value defines how much energy accumulates before a pulse is sent to the hardware channel.

Pulser module: A Pulser module takes a pulse input from any other ION module’s output register and sends a pulse to a specific hardware channel based on the pulse width. A Pulser module takes an instantaneous pulse and converts it to either a complete pulse or a transition pulse for a hardware channel.

NOTE

By default, the Form C digital outputs are normally open in the KY position upon power up. If a Form C output is used for Watt-Hour pulsing and the meter is powered down when the output is closed in the KY position, then a false transition occurs as the output returns to its default (KY) position. To compensate for the extra pulse generated on power down, the first pulse after power up is ignored, i.e., there is no transition on the Form C output until the second Watt-Hour pulse is generated by the meter. This mechanism ensures that the correct number of Watt-Hour pulses are provided, regardless of the state the Form C outputs are in when the meter is powered down.

Page 232

Digital and Analog I/O Technical Note

Page 232
Image 232
Multi-Tech Systems 7600, 7500 manual Energy Pulsing from ION Meters

7500, 7600 specifications

Multi-Tech Systems has established a strong reputation in the realm of communication technology, particularly known for its innovative products that cater to various industrial applications. Among their popular offerings are the Multi-Tech Systems 7600 and 7500 series, both designed to address the increasing demand for reliable, efficient, and flexible communication solutions in a connected world.

The Multi-Tech 7600 series is renowned for its robust design and multifunctional capabilities. One of its main features is support for multiple communication protocols, including cellular, wired, and wireless networks, ensuring seamless connectivity across different platforms. This versatility makes it an ideal choice for applications in industries such as transportation, healthcare, and logistics. The device is equipped with advanced signal processing technology, which enables it to maintain high-quality connections even in challenging environments.

On the other hand, the Multi-Tech 7500 series focuses more on the integration of IoT (Internet of Things) technologies. This series is particularly adept at connecting various smart devices, allowing for real-time data transmission and monitoring. Key features include extensive support for low-power wide-area network standards, making it an excellent option for applications that require long-range connectivity while minimizing power consumption. This characteristic is particularly advantageous for battery-operated devices deployed in remote locations.

Both series are built on versatile hardware platforms that allow for scalability and customization, catering to the unique needs of different industries. With embedded security features, including encryption and secure protocols, they provide a high level of protection for sensitive data, making them suitable for sectors that prioritize security, such as financial services and healthcare.

In terms of characteristics, both the 7600 and 7500 series are designed for ease of integration, featuring user-friendly interfaces and comprehensive development tools. This empowers developers to quickly deploy solutions and minimizes time to market. Additionally, the products offer extensive documentation and support, facilitating efficient onboarding for new users.

Overall, Multi-Tech Systems’ 7600 and 7500 series provide a powerful combination of features, technologies, and characteristics that make them standout choices for organizations looking to enhance their communication capabilities in a rapidly evolving digital landscape. Their capability to connect and interact with a wide range of devices and protocols ensures that businesses can adapt, innovate, and thrive in an increasingly connected world.