ION 7500 / ION 7600 User’s Guide

Displaying Data with Vista

 

 

Revenue Measurements Scaling

By clicking on Secondary Units (“1:1”) this control object lets the meter display and record Secondary values for kW, kVAR, and kVA (values not scaled with PT and Ct ratios). By default, the meter displays Primary values (values that using Ct, and PT scaling) for these revenue quantities.

Peak Demand Reset

The Peak Demand Reset control object allows you to clear the peak demand values logged in the meter. When the meter is in TEST mode, this object clears Revenue Test Mode demand parameters.

Master Reset

The Master Reset control object allows you to clear all the cumulative and derived quantities from the meter (including demand, peak demand, energy, revenue, and Revenue Test Mode parameters). A master reset also clears the meter’s Event log.

CAUTION

The Master Reset operation will clear all billable quantities from the meter. The Master Reset operation will also clear the logged data from the meter’s Event log.

Report Log Enable

The Report Log Enable object allows you to disable the data recorder that is factory configured to work with Reporter. Disabling this recorder reduces the processing load on the meter and the network (and the Log Server in particular).

You should only consider performing this action if the Reporter is not present with your version of ION Enterprise. For more information about Reporter, consult the online ION Enterprise Help.

Setpoints

The Setpoints diagram uses setpoints to monitor kW demand, over current and voltage unbalance levels. Vista annunciates warnings if any of the values match or exceed specified upper limits for 30 seconds or longer. Users with Level 3 authority can define the setpoint limits. All status indicators read “NOT AVAILABLE” when monitoring is disabled.

Over kW Sliding Window Demand Monitoring

Over kW demand monitoring is disabled by default.

To set the upper kW demand limit, enter the total number of kW that should be considered as an over demand condition.

Per Phase Over Current Monitoring

Over current monitoring is disabled by default.

To set the over current limits, enter the total number of Amps that should be considered as an over current condition.

Chapter 4 - Using ION Software

Page 99

Page 99
Image 99
Multi-Tech Systems 7500, 7600 manual Setpoints, Over kW Sliding Window Demand Monitoring, Per Phase Over Current Monitoring

7500, 7600 specifications

Multi-Tech Systems has established a strong reputation in the realm of communication technology, particularly known for its innovative products that cater to various industrial applications. Among their popular offerings are the Multi-Tech Systems 7600 and 7500 series, both designed to address the increasing demand for reliable, efficient, and flexible communication solutions in a connected world.

The Multi-Tech 7600 series is renowned for its robust design and multifunctional capabilities. One of its main features is support for multiple communication protocols, including cellular, wired, and wireless networks, ensuring seamless connectivity across different platforms. This versatility makes it an ideal choice for applications in industries such as transportation, healthcare, and logistics. The device is equipped with advanced signal processing technology, which enables it to maintain high-quality connections even in challenging environments.

On the other hand, the Multi-Tech 7500 series focuses more on the integration of IoT (Internet of Things) technologies. This series is particularly adept at connecting various smart devices, allowing for real-time data transmission and monitoring. Key features include extensive support for low-power wide-area network standards, making it an excellent option for applications that require long-range connectivity while minimizing power consumption. This characteristic is particularly advantageous for battery-operated devices deployed in remote locations.

Both series are built on versatile hardware platforms that allow for scalability and customization, catering to the unique needs of different industries. With embedded security features, including encryption and secure protocols, they provide a high level of protection for sensitive data, making them suitable for sectors that prioritize security, such as financial services and healthcare.

In terms of characteristics, both the 7600 and 7500 series are designed for ease of integration, featuring user-friendly interfaces and comprehensive development tools. This empowers developers to quickly deploy solutions and minimizes time to market. Additionally, the products offer extensive documentation and support, facilitating efficient onboarding for new users.

Overall, Multi-Tech Systems’ 7600 and 7500 series provide a powerful combination of features, technologies, and characteristics that make them standout choices for organizations looking to enhance their communication capabilities in a rapidly evolving digital landscape. Their capability to connect and interact with a wide range of devices and protocols ensures that businesses can adapt, innovate, and thrive in an increasingly connected world.