Multi-Tech Systems 7500, 7600 manual Downloads

Models: 7500 7600

1 372
Download 372 pages 61.31 Kb
Page 363
Image 363

ION 7500 / ION 7600 User’s Guide

Upgrading Your ION Device(s)

 

 

Choose the type of device that you want to upgrade. (In this case, it is a meter.)

This area lists all available devices of the specified type. Highlight the device(s) to upgrade.

Save/Restore framework is enabled by default, so custom frameworks are not overwritten during upgrade.

When upgrading multiple devices, specify whether the utility should halt if a certain number of device upgrades fail.

Click this button to browse your system and locate the upgrade file.

In this example, an ION 7300 Ethernet card is the device selected for upgrade.

Select the ION 7300 meter that contains the ION 7300 Ethernet card that will be upgraded.

3.Select the appropriate ION device in the List Devices of Type box. The Device Upgrade utility searches your system and lists all the supported devices in the Select Devices to Upgrade box.

4.Select the device(s) you want to upgrade from the Select Devices to Upgrade list. To make multiple selections, hold down the Ctrl key.

The Save/Restore Framework check box is selected by default so that you do not lose your current framework template during the upgrade, including any custom frameworks you may have configured. Clearing the Save/Restore Framework check box deletes the current framework template for each selected device when the firmware upgrade is complete; there is no framework configuration in the upgraded devices. It is recommended that you leave this check box selected.

If you intend to replace the meter’s framework template with the newest default template after you upgrade the firmware, then you can clear the check box. Remember to download the ION software updates to support the latest

firmware version (these can be found at HTTP://WWW.PWRM.COM/SUPPORT/

DOWNLOADS).

5.If you are upgrading multiple devices, specify in the Failure Handling area how the Device Upgrader utility responds to an unsuccessful upgrade:

Select Halt After and specify the number of devices with failed upgrades that can occur before the utility stops.

By default, the utility is set to stop after the first failed upgrade. If, for example, you increase this number to 5, the Device Upgrade utility will continue upgrading devices until the entire selection has been upgraded, or a total of five devices have failed the upgrade process.

Select Ignore All to attempt to upgrade all of the selected devices regardless of any failures.

Upgrading ION Device Firmware Technical Note

Page 363

Page 363
Image 363
Multi-Tech Systems 7500, 7600 manual Downloads

7500, 7600 specifications

Multi-Tech Systems has established a strong reputation in the realm of communication technology, particularly known for its innovative products that cater to various industrial applications. Among their popular offerings are the Multi-Tech Systems 7600 and 7500 series, both designed to address the increasing demand for reliable, efficient, and flexible communication solutions in a connected world.

The Multi-Tech 7600 series is renowned for its robust design and multifunctional capabilities. One of its main features is support for multiple communication protocols, including cellular, wired, and wireless networks, ensuring seamless connectivity across different platforms. This versatility makes it an ideal choice for applications in industries such as transportation, healthcare, and logistics. The device is equipped with advanced signal processing technology, which enables it to maintain high-quality connections even in challenging environments.

On the other hand, the Multi-Tech 7500 series focuses more on the integration of IoT (Internet of Things) technologies. This series is particularly adept at connecting various smart devices, allowing for real-time data transmission and monitoring. Key features include extensive support for low-power wide-area network standards, making it an excellent option for applications that require long-range connectivity while minimizing power consumption. This characteristic is particularly advantageous for battery-operated devices deployed in remote locations.

Both series are built on versatile hardware platforms that allow for scalability and customization, catering to the unique needs of different industries. With embedded security features, including encryption and secure protocols, they provide a high level of protection for sensitive data, making them suitable for sectors that prioritize security, such as financial services and healthcare.

In terms of characteristics, both the 7600 and 7500 series are designed for ease of integration, featuring user-friendly interfaces and comprehensive development tools. This empowers developers to quickly deploy solutions and minimizes time to market. Additionally, the products offer extensive documentation and support, facilitating efficient onboarding for new users.

Overall, Multi-Tech Systems’ 7600 and 7500 series provide a powerful combination of features, technologies, and characteristics that make them standout choices for organizations looking to enhance their communication capabilities in a rapidly evolving digital landscape. Their capability to connect and interact with a wide range of devices and protocols ensures that businesses can adapt, innovate, and thrive in an increasingly connected world.