Circuit Breakers

Three thermal circuit breakers are located behind the Control Panel access cover.

Remove Dash Panel to access circuit breakers

Fig. 37 — Circuit Breaker location

Under normal circumstance circuit breakers do not require service; they are automatically re-set once an overload condition has been corrected. If one or more breakers are cycling on/off, locate the cause of the electrical overload and repair as required.

Also see the Electrical Schematic on page 61.

Maximum Cut Depth Adjustment

The 3000 Series saws come factory-adjusted for maximum usable cut depth. However, should you desire to adjust the maximum depth:

1.Park the blade-less saw on a flat and level surface.

2.Fully lower the saw onto the Stop Bolts (see Fig. 38).

3.Measure the distance from the Blade Flanges to the surface.

4.Adjust the Stop Bolts in or out until the Blade Flanges have 1/8” to 3/16” ground clearance.

5.Ensure that both bolts are adjusted to the same setting so that the load is evenly distributed.