MQ SP-3035 CONCRETE SAW

Removing the Blade, Blade Guard & Blade Flange

WARNING

Remain Clear of all parts of saw while installing blade to prevent crush injury or death.

Verify the engine start switch is OFF before installing blade.

Tighten the 5/8” blade-mounting bolt to 100-125 foot- pounds torque.

1.Raise the saw so that the blade will clear the ground.

2.Remove blade guard. See fig. 7

3.Remove the mounting bolt from the outer flange and bushing.

4.Remove blade, outer flange and bushing simultaneously.

5.Reinstall the flange bushing, outer flange and mounting bolt.

6.Tighten the 5/8” mounting bolt to 75 foot-poundsof torque.



The blade mounting bolt on the right side of the saw (as viewed from the

operator’s position) has a left hand-thread, while the blade-mounting bolt on

NOTE

the left side of the saw has a right-hand thread.

 

 

 