Muratec F-114P service manual Overview of System

Models: F-114P F-114

1 162
Download 162 pages 3.77 Kb
Page 21
Image 21

Product spec and feature

2.2.2 Overview of System

The F-114 /F-114Pcan be divided into the following main constituent parts: Main Controller, Operator’s Panel, PC Interface, Scanner, Line Interface and Power Supply. The Main Controller uses an SPGPm processor. The Operator’s panel; (OPE) has its own MICOM which communicates serially with a UART built into the SPGPm processor. The Scanner uses an Image Processor chip (CIP4) to control the CIS. The Line Interface an FM336 integrated with the Main Board and communicates with the LIU at speeds up to 33.6Kbps. The Power Supply has

both the SMPS and HVPS integrated on one PBA.

2.2.2.1 Main Controller.

The Main Controller of the F-114 /F-114Pconsists of two ASICs (CPU, Image Processor), Scanner, Fax Modem and Print sections. Bus Control, I/O Handling, Scanner, all motor drivers and the PC Interface function is controlled by the CPU.

It uses the chorus2. These control the peripherals and the Image Processing.

2.2.2.2 Line Interface.

This part connects the set with the PSTN. The main functions of this section are Line Interface, Line Monitoring, and connection to an external phone or TAD using the built in EXT connector..

2.2.2.3 Print Engine.

The Print Engine consists of the following sections: Frame, Paper Feed, Image Transfer, Imaging Unit, Toner Cartridge, Fuser, High Voltage Supply and Scanner. The set uses an Electro Photographic process using the LSU to develop a latent image on the OPC drum. The Toner process is a single part diamagnetic process. Copy and Transfer processes use a CIS Module.

2.2.2.4 Scanner.

The scanner is designed around a 200dpi CIS module. The CIS scanning width is maximum 216mm, effective width is 208mm. The F-114operates at 200lpi, the F-114Poperates at 300 lpi.

2.2.2.5 Summary of Main Unit

- Main Board

This is an integral unit having the Engine and Video control on a single PBA. It controls the Electrophotographic Process to take the image from the PC Interface and generate the Video Data for the LSU. It also manages the transfer of that image onto paper and the fusing of the image. The main PBA unit consists of the following circuits: Motor (Paper Feed and Exit) Driver, the Clutch driver, Pre-transfer Lamp Driver, the Fuser Driver and the Fan Driver. The signals from the Paper Feed Sensor, the Paper Empty Sensor, MP sensor and Exit Sensor are input to the Main Board from the SMPS/HVPS PBA.