Product spec and feature

2.2.6.4 Fusing

The temperature of the heat roller's surface is detected according to the resistance value of the thermistor. The thermistor resistance is measured using the A/D converter and thus the CPU can determine the temperature of the heat roller. The AC power is controlled by comparing the target temperature to the value from the thermistor. If the value from the thermistor is out of the controlling range while controlling the fusing process, the error stated in the table occurs. (For the domestic model, the Q-PID method has been applied.)

Error Type

Error

Open heat error

Lower heat error

Description

When warming up, it has been lower than 68 °C over 25 sec

Standby:

It has been lower than 100°C over 25 sec

Printing:

-2 consecutive pages: it has been lower than 145°C over 5 sec

-3 consecutive page; it has been 40°C lower than the fixed fusing temperature over 4 seconds.

Over heat error

It have been higher than 220°C over 3 seconds

 

 

2.2.6.5 LSU

The LSU consists of the LD (Laser Diode) and the polygon motor control. When the printing signal occurs, the LD is turned on and the polygon motor is enabled. When the light sensor detects the beam, Hsync occurs. When the polygon motor speed becomes a normal, LReady occurs. If these two conditions are satisfied, the status bit of the LSU controller register becomes 1 ant the LSU is judged to be ready. If the two conditions are not satisfied, the error shown in the table below occurs.

Error

Description

Polygon motor error

When the polygon motor’s speed doesn’t become a normal

 

 

Hsync error

The polygon motor’s speed is normal, but the Hsync signal is not created.

 

 

2.2.7 OPE PBA

The OPE board consists of various function keys and an LCD to display set status and operator messages. A MICOM (HOLTEC HT48R50) and drives the LEDs and LCD. Communication between the OPE and the CPU on the main board is serial (related signals are /Reset, TXD, and RXD).

Service Manual

2-23

 

Page 35
Image 35
Muratec F-114P service manual Ope Pba, Fusing, 6.5 LSU, Error Type