Adjustment and Troubleshooting

15) Blank Page Print out (1)

Description: Blank page is printed.

1.Bad ground contacts in OPC and/or toner cartridge.

1.Check if the Ground-OPC or the OPC Ground Zener diode are defective or open circuit.

(set inside left side)

2.Remove contamination of the terminals on the toner cartridge and the unit.

4-40Service Manual