Problem: You are using Windows 3.1 or Windows for
Workgroups 3.11 and you get a dialog box
entitled Measure with the message,
Error -10243 The driver could
not locate or open the
configuration file, or the
format of the configuration
file is not compatible with
the currently installed
driver.
Solution: Delete the WDAQCONF.CFG file in your
Windows directory. Then reconfigure your
hardware using the NI-DAQ Configuration
Utility. If the problem persists, contact
National Instruments for an updated version
of the NI-DAQ driver.
Problem: You get a dialog box entitled Measure with
a message that begins Fatal error.
Solution: Congratulations! It is likely that you have
found a deficiency in our code! Please write
down the information in the dialog box as
well as the actions that you took preceding
the error. Try to reproduce the error. Then,
call National Instruments technical support.
Problem: After you remove the Measure Data
Acquisition Add-In in the Add-Ins dialog
box, a dialog box entitled Microsoft Excel
appears with the message Cannot
access ‘DAQ.XLA’.
Solution: Click on the Cancel button. This behavior,
which occurs because of Microsoft Excel or
the OLE libraries, is harmless and you can
safely ignore it.