NEAX2400 IPX ISDN Features and Specifications
Page 42 NDA-24311, Issue 1
C-129 Call Forwarding - Don’t Answer - PRI
C-129 Call Forwarding - Don’t Answer - PRI
General Description
This feature permits a call from an ISDN network to an unanswered station to be forwarded to a predesignated
station, or to the Attendant, when the called station does not answer after a predetermined time interval.
Operating Procedure
To set CALL FORWARDING - DON’T ANSWER - PRI from an individual station
1. Lift the handset; receive dial tone.
2. Dial the specific CALL FORWARDING - DON’T ANSWER access code; receive special dial tone.
3. Dial the desired target telephone number; receive service set tone.
To cancel CALL FORWARDING - DON’T ANSWER - PRI from an individual station
1. Lift the handset; receive dial tone.
2. Dial the specific CALL FORWARDING - DON’T ANSWER cancel code; receive service set tone.
To set CALL FORWARDING - DON’T ANSWER - PRI from the ATTENDANT CONSOLE [A-3]
1. Press an idle loop key.
2. Dial the specific CALL FORWARDING - DON’T ANSWER access code; receive special dial tone.
3. Dial the TENANT [T-12] number (two digits).
4. Dial the originating telephone number.
5. Dial the desired target telephone number; receive service set tone.
To cancel CALL FORWARDING - DON’T ANSWER - PRI from the ATTENDANT CONSOLE [A-3]
1. Press an idle loop key.
2. Dial the specific CALL FORWARDING - DON’T ANSWER cancel code; receive special dial tone.
3. Dial the TENANT [T-12] number (two digits).
4. Dial the originating telephone number; receive service set tone.
Service Conditions
1. This feature may be set and cancelled by either the user or the Attendant.
2. When the Attendant extends a call to a station that has set CALL FORWARDING - DON’T ANSWER,
the called station rings for 30 seconds. If, a fter this time , the cal l ha s not bee n a nswe red, AUT OMAT IC
RECALL [A-8] is activated. If desired, th is timing can be changed throug h the VARIABLE TIMING
PARAMETERS [V-1] feature.
3. Stations are assigned this feature according to CLASS OF SERVICE - INDIVIDUAL [C-15]
programming in system data.
4. A station programmed for access to CALL FORWARDING - DON’T ANSWER is automatically allowed
CALL FORWARDING - BUSY LINE [C-2].
5. There is no limitation to the number of stations that can set the CALL FORWARDING - DON’T
ANSWER simultaneously.
6. CALL FORWARDING - DON’T ANSWER can be provided on either a system or an individual basis.
That is, when a station does not answer, the CALL FORWARDING - DON’T ANSWER setting by system
is available if the station has not set this servi c e .
7. Individual CALL FORWARDING - DON’T ANSWER takes priority over system basis Call Forwarding.
8. Call Forwarding on a system basis allows direct incoming trunk calls which encounter a Don’t Answer
condition to be forwarded to a predetermined station or the ATTENDANT CONSOLE [A-3].