NEAX2400 IPX ISDN Features and Specifications
Page 96 NDA-24311, Issue 1
N-29 Night Connection Outside - System - PRI
N-29 Night Connection Outside - System - PRI
General Description
This is a night transfer service o n a system basis enabling a rin g down call to be transferred to a preselected station,
outside the NEAX2400 IPX via ISDN network, when Night mode has been set.
Operating Procedure
1. The Attendant sets Night mode.
(Night key, PB, Jack Extraction, MB)
2. Ring down call terminates from a trunk.
3. The call is transferred to another station in accordance with NIGHT CONNECTION OUTSIDE -
SYSTEM data.
Service Conditions
1. The priority of this service is higher than TRUNK ANSWER FROM ANY STATION (TAS) [T-8]
service, but lower than DIRECT-IN TERMINATION (DIT) [T-7] and NIGHT CONNECTION - FIXED
[N-1] services. Therefore, if DIT [D-7] and NIGHT CONNECTION - FIXED [N-1] are set, this service
is not activated.
2. If the terminating side is a ring down trunk, a release signal cannot be sent out after communication is
established; so the trunk to which the call is transferred must be capable of sending back a release signal.
3. This service cannot be used in combination with CONSECUTIVE SPEED CALLING - SYSTEM [C-62]
and SPEED CALLING - OVERRIDE - SYSTEM [S-61] service.
4. The call transfer destination can be fixed on a tenant basis.
5. Whether to activate this service or not can be determined in system data on a tenant basis.
6. The call transfer destination is assigned using Speed Calling numbers.
7. Speed Calling numbers assigned as the transfer destination can be used f or SPEED CALLING - SYSTEM
[S-3] feature.
8. When night transfer occurs, incoming/outgoing routes will be restricted.