Chapter 6 Troubleshooting 329
Using the Business Policy Switch 2000 Version 1.2
Green On The switch is connected to the upstream units Cascade A
In connector.
Amber On This unit has detected a problem with the switch
connected to the cascade up connector. In order to
maintain the integrity of the stack, this unit has bypassed
its upstream neighbor and has wrapped the stack
backplane onto an alternate path.
Amber
or
Green
Blinking Incompatible software revision or unable to obtain a unit
ID (Renumber Stack Unit table full). The unit is on the ring
but cannot participate in the stack configuration.
Cas Dwn Stack mode Off The switch is in standalone mode.
Green On The switch is connected to the downstream units
Cascade A Out connector.
Amber On This unit has detected a problem with the switch
connected to the cascade down connector. In order to
maintain the integrity of the stack, this unit has bypassed
its downstream neighbor and has wrapped the stack
backplane onto an alternate path.
Amber
or
Green
Blinking Incompatible software revision or unable to obtain a unit
ID (Renumber Stack Unit table full). The unit is on the ring
but cannot participate in the stack configuration.
Tabl e 59 Business Policy Switch LED descriptions (continued)
Label Type Color State Meaning