120 Bandwidth Management
Command Description
Configure the zone-to-zone record validity time interval, where:
•Zone = 1-255
•Interval = 1-(48)-255
CHG CD <Zone> <Cd>
Change the Cd coefficient in the formula that determines how quickly an alarm
reduces the Sliding Maximum bandwidth for the identified zone, where:
•Zone = 1-255
•Cd = Cd coefficient = 1-(50)-100
CHG CPL <Zone> <Cpl>
Change the Cpl coefficient in the formula that determines how quickly an alarm
reduces the Sliding Maximum bandwidth for the identified zone, where:
•Zone = 1-255
•Cpl = Cpl coefficient = 1-(50)-100
CHG CJ <Zone> <Jitter>
Change the Cj coefficient in the formula that determines how quickly an alarm
reduces the Sliding Maximum bandwidth for the identified zone, where:
•Zone = 1-255
•Jitter = Jitter coefficient = 1-(50)-100
CHG CQOS <Zone> <QoS>
Change the QoS coefficient in the formula that determines how quickly an alarm
reduces the Sliding Maximum bandwidth for the identified zone, where:
•Zone = 1-255
•QoS = QoS coefficient = 1-(50)-100
CHG CR <Zone> <Cr>
Change the Cr coefficient in the formula that determines how quickly an alarm
reduces the Sliding Maximum bandwidth for the identified zone, where:
•Zone = 1-255
•Cr = Cr coefficient = 1-(50)-100
Nortel Communication Server 1000
Main Office Configuration Guide forSRG 50
NN43001-307 02.02 Standard
Release 5.0 3 December 2007
Copyright© 2005-2007, Nor tel Networks
.