Maintenance 185
Command Description
ENL ZBR <zone> [ALL] [LOC][ESA][TIM][ALT] Enable features for the branch office zone. If you do
not input features, then all are enabled.
DIS ZBR [ALL] [LOC][ESA][TIM][ALT] Disable features for the branch office zone. If you do not
input features, then all are disabled.
The system responds with ok, if operation is successful.
LD 117 Change and Print Zone Alarm Suppression Time Interval
Command Description
CHG ZAST <zone> <Alarm Suppression Interval>
Change Suppression Time Interval for QoS alarms related
to Alternative Call Routing for NBWM feature for zone
specified. Time Interval is measured in seconds from the
time the last alarm was printed.
Default is 0. Range is 0 - 3600 seconds.
PRT ZAST <zone> Print Suppression Time Interval for QoS alarms related
to Alternative Call Routing for NBWM feature for zone
specified. No entry for zone number results in printout for
all zones.
Sample printout:
#Alarms Suppression Time
10 50
11 0
12 1000
Where # is the column header for zone number.
Element Manager maintenanceEnable branch office behavior for a zone
Youcan configure the Alternative Call Routing for NBWM feature while you
configure the zone’s branch office behavior.
Procedure 13
Enabling behavior at a zone
Step Action
1Fromthe navigator, click System > Maintenance. TheMaintenance
web page appears. See Figure 74 "Maintenance web page" (page
181).
Nortel Communication Server 1000
Main Office Configuration Guide forSRG 50
NN43001-307 02.02 Standard
Release 5.0 3 December 2007
Copyright© 2005-2007, Nor tel Networks
.