2.7.3 DIP Switch Setup: Ethernet - Coordinator

4

1

1)

N/C

2)

To change to default factory settings

3)

To enable/disable DHCP

 

OFF

4)

N/C

OFF ON1

 

ON

8

1 2 3

(Shown in

 

SERIAL DEFAULT DHCP 4TERMINAL

"OFF" Position)

Coordinator

 

 

Figure 2.9 Ethernet - 4 Position DIP Switch Setup

To set the Coordinator to factory default settings:

1)Slide DIP switch #2 to ON position.

2)Power the Coordinator on and wait about 10 seconds until the Coordinator fully boots up.

3)Set the DIP switch #2 back to OFF position (it does not matter if the Coordinator is powered ON or OFF, just make sure that the DIP switch is set to OFF, otherwise, every time the unit is power-cycled the factory settings will take over.