4.3.8 Sensor Setup (continued)

SETUP- http://192.168.1.200

SENSOR SETUP

# Check Sensor Name Update Seconds

Units

Power

0

ABCDEFGH

10

-

-

1

ABCDEFGH

10

-

-

2

LAB 100

10

C,mbar Battery

3

ABCDEFGH

10

-

-

4

ABCDEFGH

10

-

-

5

ABCDEFGH

10

-

-

6

ABCDEFGH

10

-

-

7

ABCDEFGH

10

-

-

Click on Sensor # to modify Sensor Parameters

Firmware

0

0

2.0

0

0

0

0

0

Update Checked Box

Take Readings

View Charts

Select Another Group

Main Menu

 

Figure 4.18 Sensor Setup

#: Sensor ID configured by dip switches on the End Device. Click on the number to view

and modify Sensor Parameters. See Figure 4.9.

Check: Each check box controls whether or not readings from the End Device will be

outputted. If unchecked the readings from the End Device will not be displayed on the

“Readings”, “Chart”, and “Diagnostic” pages. Nor it will respond to Telnet connection.

Sensor Name: Name of an End Device shows on the “Readings” and “Chart” pages,

this is a text field and can take up to 8 alphanumeric characters.

Updates Seconds: How often an End Device sends its data to the Coordinator.

Units: Type of data and the corresponding units. Units of measurement form sensors

inside an End Device that has joined the network will be displayed. [ ºC, ºF or % or

mbar, inHg. mmHg ].

 

Firmware: Version number of the End Device firmware

Update Checked Box:

After checking/unchecking the boxes, make sure this is clicked

to save the changes.

35

 

Page 41
Image 41
Omega Vehicle Security zSeries manual Sensor Setup, Update Checked Box