Appendix F

TELNET COMMANDS TABLE

 

 

 

 

Command

 

Device / Group ID

 

Description (see notes below if *)

 

Example

 

 

 

 

 

 

 

ERDB

 

Device ID: 000 – 031

 

Get sensor readings of an End Device

 

Get reading for

 

 

 

 

 

 

 

 

 

sensor 15 ERDB015

 

 

ERDG

 

Group ID: 00A - 00D, ALL

Get sensor readings of a group /

 

Get readings for all

 

 

 

 

 

 

 

groups of sensors

 

group B ERDG00B

 

 

EQNF

 

Device ID: 000 – 031

 

Get name, * internal state and firmware

 

Get name, for sensor

 

 

 

 

 

 

 

version of an End Device

 

15 EQNF015

 

 

EQNG

 

Group ID00A - 00D, ALL

Get name, * internal state and firmware

 

Get name, for all

 

 

 

 

 

 

 

version of a group/all groups of sensors

 

sensors EQNGALL

 

 

EQPE

 

Device ID: 000 – 031

 

Get sleep period, battery voltage, signal

 

Get sleep period, for

 

 

 

 

 

 

 

strength, success, network address and

 

sensor 15 EQPE015

 

 

 

 

 

 

 

parent address of an End Device

 

 

 

 

EQPG

 

Group ID: 00A - 00D

 

Get sleep period, battery voltage, signal

 

Get sleep period, of

 

 

 

 

 

 

 

strength, success, network address and

 

group B EQPG00B

 

 

 

 

 

 

 

parent address of a group / all groups

 

 

 

 

 

 

 

 

 

of sensors

 

 

 

 

ESPD

 

Device ID: 000-031, ALL

Set the sleep period for an End Device

 

Set sensor 15’s sleep

 

 

 

 

 

 

 

/ all sensors *1

 

period to 30 seconds

 

 

 

 

 

 

 

 

 

ESPD015 30

 

 

ESNM

 

Device ID: 000 – 031

 

Set the name of an End Device *2

 

Set the name of

 

 

 

 

 

 

 

 

 

sensor 15 ESNM015 z15

 

 

ERST

 

Device ID: 000 – 031, ALL

Reset an End Device / all sensors

 

Reset all sensors

 

 

 

 

 

 

 

 

 

ERSTALL

 

 

ESTR

 

Device ID: 000 – 031, ALL

Request End Device(s) to go into

 

Put all sensors into

 

 

 

 

 

 

 

identify mode

 

identify mode ESTRALL

 

 

ESTP

 

Device ID: 000 – 031, ALL

Request End Device(s) to resume

 

Resume all sensor to

 

 

 

 

 

 

 

normal operation

 

normal operation ESTPALL

 

 

CRST

 

 

 

 

Reset wireless network

 

Reset network CRST

 

 

CSTS

 

 

 

 

Get personal network ID and channel

 

Get wireless network

 

 

 

 

 

 

 

information

 

information CSTS

 

 

FACTORY

 

 

 

 

Sets the Coordinators Ethernet configur-

 

FACTORY xxxxxxxx

 

 

 

 

 

 

 

AdminPassword

 

 

ations to Factory Defaults

 

xxxxxxxx is the Admin

 

 

 

 

 

 

 

 

 

Password

 

*1 Argument: 1 – 32767 (1 seconds to about 9 hours)

 

 

 

*2 Argument: xxxxxxxx (8 characters)

 

 

 

 

61

Page 67
Image 67
Omega Vehicle Security zSeries manual Telnet Commands Table, Erdg