4.3.12 Output Selection (Level 2)

iRIS 220 / iRIS 320, V1.19 User Guide - 36

Option 4

When this option is selected you will be prompted to enter a time in seconds to delay alarm activation. This can be used to implement hysteresis for Analog data sources. If the data source is one of the internal counters then this time is used to totalise individual sample values. If the total over the given alarm duration is above the trigger level then an alarm is generated. Typically this feature is used for rainfall alarms.

> Duration (min)=

4.3.12 Output Selection (Level 2)

The Output Selection menu is where you select the output you want to configure. From this menu, you can see at a glance which outputs are enabled.

*Output Selection

0 Exit

1 Output #1 (Enabled)

2 Output #2 (Disabled)

>

Option 0

Select this option to return to the main menu.

Option 1

Select this option to display the set-up menu for Output 1.

Option 2

Select this option to display the set-up menu for Output 2.

4.3.13 Output Cfg (Level 3)

The Output Cfg menu is used to configure each digital output. In the example below, output 1 is being configured.

*Digital Output 1 Cfg

0 Exit

1 Enable [Yes]

2 Polarity [Normal]

3 Mode [Schedule]

4 Duration [30sec]

5 Frequency [1min]

6 Start Time [0000]

7 End Time [2359]

>

Option 0

Select this option to return to the Output Selection menu.

Option 1

When this option is selected you will be prompted to enable/disable the output.

> Enable (0:No 1:Yes)=

Enter a value of 0 if you want to disable the output. Enter a value of 1 if you want to enable it.

36